A new low pressure ‘quasi-steady’ pulse technique for determining the airtightness of buildings has been developed further and compared with the standard blower-door technique for field-testing a range of typical UK homes. The reported low pressure air pulse unit (APU) has gone through several development stages related to optimizing the algorithm, pressure reference and system construction. The technique, which is compact, portable and easy to use, has been tested alongside the standard blower-door technique to measure the airtightness of a range of typical UK home types. Representative of the UK housing stock, the homes mostly have low levels of airtightness, resulting in poor energy performance, poor indoor air quality and poor thermal comfort. Some of these homes have been targeted for retrofitting and a quick, low cost and simple method for accurately determining their airtightness has clear advantages for correctly predicting the benefits of any improvements. A comparison between the results given by the two techniques is presented and the field trials indicate that the latest version of the pulse technique is reliable for determining building leakage at low pressure. Repeatability of multiple APU tests in the same house is found to be within +/-5% of the mean. A test where the leakage is increased by a known amount shows the APU is able to measure the change more accurately than the blower-door test. The APU also gives convenience in practical applications, due to being more compact and portable, plus it doesn’t need to penetrate the building envelope. The field trials demonstrate the pulse test has the potential to be a feasible alternative to the standard blower-door test.
机译:进一步开发了一种用于确定建筑物气密性的低压“准稳定”脉冲技术,并将其与用于对一系列典型英国房屋进行现场测试的标准鼓风机门技术进行了比较。所报告的低压空气脉冲单元(APU)经历了与优化算法,压力参考和系统构造有关的几个开发阶段。该技术紧凑,便携且易于使用,已与标准的鼓风机门技术一起进行了测试,以测量多种典型英国家庭类型的气密性。作为英国房屋存量的代表,这些房屋的气密性水平低,导致能源性能差,室内空气质量差和热舒适性差。这些房屋中的一些已经成为翻新的目标,并且快速,低成本和简单的方法来准确确定其气密性具有明显的优势,可以正确预测任何改进的收益。给出了这两种技术给出的结果之间的比较,并且现场试验表明,最新版本的脉冲技术对于确定低压下的建筑物泄漏是可靠的。同一家中的多个APU测试的重复性被发现在平均值的+/- 5%之内。泄漏增加已知量的测试表明,APU比鼓风机门测试能够更准确地测量变化。由于更紧凑,更便携,APU还为实际应用提供了便利,而且它不需要穿透建筑物的围护结构。现场试验表明,脉冲测试有可能替代标准的鼓风机门测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号