首页> 外文OA文献 >Design of a practical model-observer-based image quality assessment method for x-ray computed tomography imaging systems
【2h】

Design of a practical model-observer-based image quality assessment method for x-ray computed tomography imaging systems

机译:X射线计算机断层摄影成像系统基于模型观察者的实用图像质量评估方法的设计

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The use of a channelization mechanism on model observers not only makes mimicking human visual behavior possible, but also reduces the amount of image data needed to estimate the model observer parameters. The channelized Hotelling observer (CHO) and channelized scanning linear observer (CSLO) have recently been used to assess CT image quality for detection tasks and combined detection/estimation tasks, respectively. Although the use of channels substantially reduces the amount of data required to compute image quality, the number of scans required for CT imaging is still not practical for routine use. It is our desire to further reduce the number of scans required to make CHO or CSLO an image quality tool for routine and frequent system validations and evaluations. This work explores different data-reduction schemes and designs an approach that requires only a few CT scans. Three different kinds of approaches are included in this study: a conventional CHO/CSLO technique with a large sample size, a conventional CHO/CSLO technique with fewer samples, and an approach that we will show requires fewer samples to mimic conventional performance with a large sample size. The mean value and standard deviation of areas under ROC/EROC curve were estimated using the well-validated shuffle approach. The results indicate that an 80% data reduction can be achieved without loss of accuracy. This substantial data reduction is a step toward a practical tool for routine-task-based QA/QC CT system assessment. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
机译:在模型观察者上使用通道化机制不仅使模仿人类的视觉行为成为可能,而且减少了估计模型观察者参数所需的图像数据量。通道化的Hotelling观测器(CHO)和通道化的扫描线性观测器(CSLO)最近已用于分别评估CT图像质量,以进行检测任务和组合的检测/估计任务。尽管通道的使用大大减少了计算图像质量所需的数据量,但CT成像所需的扫描次数对于常规使用仍然不切实际。我们希望进一步减少使CHO或CSLO成为用于常规和频繁的系统验证和评估的图像质量工具所需的扫描次数。这项工作探索了不同的数据缩减方案,并设计了一种只需要进行几次CT扫描的方法。本研究包括三种不同类型的方法:具有大样本量的常规CHO / CSLO技术,具有较少样本的常规CHO / CSLO技术以及我们将展示的方法需要较少的样本来模拟具有大样本量的常规性能样本量。 ROC / EROC曲线下面积的平均值和标准偏差是使用经过充分验证的混洗方法估算的。结果表明,可以实现80%的数据缩减,而不会损失准确性。数据的大量减少是朝着基于日常任务的QA / QC CT系统评估实用工具迈出的一步。 (C)2016年光电仪器工程师学会(SPIE)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号