首页> 外文OA文献 >Counterfeit Tablet Investigations: Can ATR FT/IR Provide Rapid Targeted Quantitative Analyses?
【2h】

Counterfeit Tablet Investigations: Can ATR FT/IR Provide Rapid Targeted Quantitative Analyses?

机译:假冒片剂调查:ATR FT / IR能否提供快速有针对性的定量分析?

摘要

Counterfeit medicines are now a global public health problem. In developed countries up to 1% of medicines are reported to be counterfeit whilst in developing countries the level is ~30-40%. In this research the potential of Attenuated Total Reflection (ATR) FT/IR techniques to provide rapid quantitative analyses of suspect tablet formulations is reported. Unlike conventional tablet analyses where several tablets are crushed and solvent extracted, ATR FT/IR methods require that only a single tablet be crushed prior to analysis. This provides a considerable time saving over the solvent extraction protocols cited in the British Pharmacopoeia. Reference ATR FT/IR spectra of the active pharmaceutical ingredient (API) and excipients, from crushed tablets, were recorded forudidentification purposes. Quantitative data was obtained from ATR FT/IR spectra of calibrated mixtures of the API in the excipients. Tablet samples from various countries, India, Africa, China, Belgium and the UK were examined.Initial results showed the API could be identified down to ca 5% w/w of the tablet. Quantification was linear withudselected characteristic peak areas for each API/excipient mixture. The analysis of the tablet samples generally showed good agreement with expectation. This was confirmed by conventional extractive analyses followed by UV quantification. ATR FT/IR can therefore identify counterfeit tablets rapidly without the need for solvents. Whilst LCMS/udMS and NMR techniques may be the ‘gold standards’ of the analytical world they are of much reduced value in sub-Saharan African countries whereas a portable ATR FT/IR may prevent the use of counterfeit antimalarial tablets and contribute to improvements in patient health.
机译:假药现在是全球性的公共卫生问题。据报告,在发达国家,高达1%的药品是伪造的,而在发展中国家,该水平约为30-40%。在这项研究中,报告了衰减全反射(ATR)FT / IR技术为可疑片剂的快速定量分析的潜力。与常规的片剂分析不同,在常规的片剂分析中,需要将几块片剂压碎并萃取溶剂,而ATR FT / IR方法只需要在分析前将一块片剂压碎即可。与英国药典中引用的溶剂萃取方案相比,这可节省大量时间。记录了来自压碎片剂的活性药物成分(API)和赋形剂的参考ATR FT / IR光谱,以供识别。从辅料中API校准混合物的ATR FT / IR光谱获得定量数据。对来自不同国家,印度,非洲,中国,比利时和英国的片剂样品进行了检查,初步结果表明,API的含量低至片剂的5%w / w。定量与每个API /赋形剂混合物的未选择特征峰面积呈线性关系。片剂样品的分析通常显示出与预期的良好一致性。通过常规的萃取分析,然后进行UV定量,可以证实这一点。因此,ATR FT / IR无需溶剂即可快速识别假冒片剂。尽管LCMS / udMS和NMR技术可能是分析领域的“黄金标准”,但它们在撒哈拉以南非洲国家的价值却大大降低,而便携式ATR FT / IR可能会阻止使用仿冒的抗疟疾药片并有助于改进在患者健康方面。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号