A modular data acquisition system for high resolution clinical PET scanners

机译:用于高分辨率临床PET扫描仪的模块化数据采集系统

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

En las últimas dos décadas, la Tomografía por Emisión de Positrones (PET) ha demostrado ser una modalidad clave para el estudio de la biología del cúncer y trastornos cardíacos, y para la realizaciún imágenes moleculares, una tecnica que permite la terapia individualizada de la enfermedad [Weissleder01]. La mejor característica de la PET es su sensibilidad: es la tecnica que proporciona imúagenes moleculares con la mayor sensibilidad, y las imúagenes de cuerpo entero que produce no pueden ser igualadas por otras modalidades [Hoh97, Chae07]. Por otra parte, la PET no proporciona referencias anatómicas, lo cual es un problema facilmente resoluble a traves de su integraciún o coregistro con la tomografía computarizada de rayos X (CT) [Lu07]. Ademas, en com- paraciún con otras modalidades de imagen, la PET se caracteriza por bajas estadísticas de conteo (es decir, desintegraciones por unidad de tiempo), lo cual generalmente limita la resoluciún de la imagen. Sin embargo, detectores con geometrías dedicadas permiten solventar ester problema, y producir exce¬lentes resultados [Humm03]. Dos ejemplos destacables de especializacion, que tomaremos como aplicaciones de referencia, son la Mamografía por Emision de Positrones (PEM) y la monitorizacion en línea de dosis en hadroterapia (in-beam PET o, brevemente, ibPET). Las amplias posibilidades de especializacion tienen, sin embargo, una con¬trapartida: es necesario el desarrollo de sistemas de adquisicion igualmente especializados, cuyo coste y prestaciones puede impedir de hecho conseguir las ventajas teúricas proporcionadas por una geometría dedicada. El objetivo de esta tesis doctoral es proponer una nueva arquitectura tecnologica flexible, capaz de obtener prestaciones similares al estado del arte en distintas aplicaciones, a traves de una plataforma de adquisiciún compacta y eficiente en coste, adecuada para PEM e ibPET. En primer lugar, se exploraran el estado del arte y los problemas que han evitado la amplia difusion de equipos PET dedicados en entornos clínicos. Es¬pecial atenciún se dedicara a las soluciones tecnologicas y las características de los escaneres PEM anteriores. Se revisara tambien la situation de losequipos ibPET, especialmente las prestaciones requeridas para soportar efi¬cazmente la planificación de tratamiento en hadroterapia. En segundo lugar, se tratara un diseño conceptual propuesto como solucion al problema. Se propondrán y justificaran diferentes alternativas, con el fin de maximizar la eficiencia de detection y minimizar el coste. A traves de una serie de prototipos intermedios, se implementaran y caracterizarán las opciones de disenño elegidas. Por ultimo, se propondráa el disenño e implementacioán de un prototipo final de sistema de adquisicioán. El equipo en cuestiáon integraráa y extenderaá la soluciones validadas con los prototipos anteriores. x La investigation llevada a cabo durante esta tesis ha permitido realizar un sistema de adquisicion, con prestaciones al estado del arte, apto para el uso de PET dedicado en el entorno clínico del paciente, y que apoyara la investigation en PEM e ibPET. udSummary In the last two decades, Positron Emission Tomography (PET) showed to be a key modality to interrogate biology for cancer and cardiac disorders, and to perform molecular imaging, a technology that permits individualized therapy of disease [Weissleder01]. PET's best characteristic is sensitivity: it is the most sensitive tech¬nique for medical molecular imaging, and the whole-body images it produces are unequalled by any other modality [Hoh97, Chae07]. Of course, it lacks anatomical reference, but this is a problem that can be easily overcome with X-ray (CT) (Computed Tomography) integration or coregistration [Lu07]. Moreover, even if PET uses relatively low statistics with respect to other modalities, which generally limits image resolution, it can produce excellent results by using dedicated detector geometries [Humm03]. Two remarkable examples for this kind of system specialization, that we will take as refer¬ence applications, are Positron Emission Mammography (PEM) and in-beam PET (ibPET) for dose delivery monitoring in hadrontherapy. However, the wide range of design possibilities has a counter effect: it re¬quires the development of specifically tailored acquisition systems, whose cost and performances could actually prevent the achievement of the theoretical advantages obtainable with a specialized detector assembly. This doctoral thesis aims at proposing an alternative technological archi¬tecture, able to achieve state of the art PET imaging performances by means of a compact, cost efficient acquisition platform, suitable for its adoption in both PEM and ibPET. Firstly, the state of the art and the controversies that prevent the broad use of dedicated PET in clinics will be explored. Special attention will be paid to the technological solutions and characteristics of previous PEM scanners. It will be also reviewed the current status of ibPET, with particular focus on the performances required to effectively support treatment planning in hadrontherapy. Secondly, a conceptual design solution will be discussed. Various alter-natives will be proposed and justified, with the aim of maximizing detection ud efficiency and minimize system cost. Through a series of intermediate pro¬totypes the various design choices are implemented and characterized. Thirdly, a final prototype of the acquisition system is designed and im¬plemented. This piece of hardware integrates and extends the solutions that have been validated through the previous systems. The research carried out during this thesis has allowed realizing a state of the art acquisition system that is suitable for specialized PET imaging in the clinical environment of the patient, and that will be used for further research in PEM and ibPET imaging. ud
机译:在过去的二十年中,正电子发射断层扫描(PET)已被证明是研究癌症生物学和心脏疾病以及分子成像技术的关键方法,分子成像技术可对疾病进行个性化治疗[Weissleder01]。 PET的最大特点是它的灵敏度:这是一种为分子图像提供最高灵敏度的技术,其产生的全身图像无法与其他形式相匹配[Hoh97,Chae07]。另一方面,PET不提供解剖学参考,这是通过与X射线计算机断层扫描(CT)集成或共配准可以轻松解决的问题[Lu07]。另外,与其他成像方式相比,PET的特点是计数低(即每单位时间衰减),这通常会限制图像分辨率。但是,具有专用几何形状的检测器可以解决此问题,并产生出色的结果[Humm03]。我们将作为参考应用的两个著名的专业化例子是正电子放射乳腺摄影(PEM)和hadrotherapy中的在线剂量监测(束内PET或简称为ibPET)。但是,专业化的广泛可能性是对等的:开发同样专业化的采集系统是必要的,其成本和收益实际上可能阻止实现专用几何结构提供的理论优势。本博士论文的目的是提出一种新的灵活的技术架构,该架构能够通过适用于PEM和ibPET的紧凑且经济高效的采集平台,在不同应用中获得与现有技术类似的收益。首先,将探讨阻碍专用PET设备在临床环境中广泛使用的技术水平和问题。将特别关注以前的PEM扫描仪的技术解决方案和功能。还将审查ibPET设备的状况,尤其是有效支持hadrotherapy中的治疗计划所需的收益。其次,将讨论提出的概念设计作为该问题的解决方案。为了最大化检测效率和最小化成本,将提出并证明不同的替代方案。通过一系列中间原型,将实施和设计所选的设计选项。最后,将提出采购系统最终原型的设计和实施。有问题的团队将集成和扩展经过先前原型验证的解决方案。 x在本论文中进行的研究使得有可能实施一种采集系统,该采集系统具有最先进的优势,适用于患者临床环境中专用PET的使用,并将支持PEM和ibPET的研究。总结在过去的二十年中,正电子发射断层扫描(PET)是询问癌症和心脏疾病生物学并进行分子成像的一种关键方式,这项技术可以对疾病进行个体化治疗[Weissleder01]。 PET的最大特点是灵敏度:它是医学分子成像技术中最敏感的技术,其产生的全身图像是其他任何形式都无法比拟的[Hoh97,Chae07]。当然,它缺乏解剖学上的参考,但这是可以通过X射线(CT)(计算机断层扫描)集成或配准轻松解决的问题[Lu07]。此外,即使PET使用的其他形式的统计信息相对较低(通常会限制图像分辨率),也可以通过使用专用的检测器几何形状[Humm03]来产生出色的结果。我们将作为参考应用的此类系统专业化的两个非凡示例是正电子放射乳腺摄影(PEM)和束流PET(ibPET),用于在强子疗法中监测剂量输送。但是,广泛的设计可能性会产生反作用:需要开发专门定制的采集系统,其成本和性能实际上可能阻止实现通过专用探测器组件获得的理论优势。该博士论文旨在提出一种替代性技术架构,该架构可通过紧凑,经济高效的采集平台实现最先进的PET成像性能,该平台适用于PEM和ibPET。首先将会探讨阻止专用PET在临床中广泛使用的最新技术和争议。将特别关注以前的PEM扫描仪的技术解决方案和特性。还将审查ibPET的当前状态,特别关注有效支持强子疗法治疗计划所需的性能。其次,将讨论概念设计解决方案。各种替代方案将被提出并证明其合理性,目的是最大化检测效率并最小化系统成本。通过一系列中间原型,可以实现和设计各种设计选择。第三,设计并实现了采集系统的最终原型。该硬件集成并扩展了已通过先前系统验证的解决方案。论文进行期间的研究已经允许实现一种最先进的采集系统,该采集系统适用于患者临床环境中的专用PET成像,并将用于PEM和ibPET成像的进一步研究。 ud

著录项

  • 作者

    Sportelli Giancarlo;

  • 作者单位
  • 年度 2010
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号