首页> 外文OA文献 >Operation of Biofilter with Mixed Agricultural Residue as Filter Material: Effects of Humidification and Inlet Hydrogen Sulfide Volume fraction on the Performance
【2h】

Operation of Biofilter with Mixed Agricultural Residue as Filter Material: Effects of Humidification and Inlet Hydrogen Sulfide Volume fraction on the Performance

机译:以农业残余物为滤料的生物滤池的运行:加湿和入口硫化氢体积分数对性能的影响

摘要

Mixed agricultural residue, inoculated with aerobic sulfide oxidizing microbial consortium, was used as biofilter media to study the removal efficiency (,R) of hydrogen sulfide (H2S). The effect of humidification and inlet H2S volume fraction on the performance of biofilter was also investigated. A 3.9 l bench scale biofilter was continuously operated to treat air containing H2S gas in the range of = 275 to 2833 · 10–6 for 150 days. ,R of 99 % was obtained at = 2020 · 10–6 of inlet H2S volume fraction during continuous operation with humidification. However, ,R dropped to 51 % when the inlet H2S fraction increased beyond = 2020 · 10–6. A maximum elimination productivity of 91 g m–3 H2S of filter bed h-1 and inlet mass loading rate of 91 g m-3 H2S of filter bed h-1 was achieved when the tEBRT was in the range of 15 – 155 s. The filter was operated without the humidifier at the inlet H2S fraction of = 2020 · 10–6 and observed that ,R dropped to 51 % due to the drop in moisture of the filter material. However, R could be recovered up to 83 % upon reintroduction of humidifier into the circuit of biofiltration process indicating, that humidification of the waste gas was essential to achieve the highest possible ,R at particular inlet H2S fraction. The filter recorded ,R above 99 % even in the acidic phase at = 2020 ·10–6 of inlet H2S fraction without intermittent washing. The gas dispersion characteristics were comparable to the previously tested bed materials, offering low-pressure drop across the biofilter in the range of 21 – 74mm of H2O per meter height of packing material.
机译:接种好氧硫化物氧化微生物菌群的混合农业残留物被用作生物滤料,以研究硫化氢(H2S)的去除效率(R)。还研究了加湿和入口H2S体积分数对生物滤池性能的影响。连续运行3.9升台式生物滤池,处理含硫化氢气体的空气(范围为275至2833·10-6)持续150天。在加湿连续运行期间,在= 2020·入口H2S体积分数的10–6时,获得99%的R。但是,当入口的硫化氢含量增加超过2020·10–6时,R降至51%。当tEBRT在15 – 155 s范围内时,滤床h-1的最大消除生产率为91 g m-3 H2S,滤床h-1的入口质量负载率为91 g m-3 H2S。在入口H2S比例= 2020·10–6的情况下,该过滤器在没有加湿器的情况下运行,并且观察到,由于过滤材料中水分的下降,R降至51%。但是,在将加湿器重新引入生物过滤过程的回路中时,R的回收率可高达83%,这表明废气的加湿对于在特定的进口H2S比例下获得尽可能高的R是必不可少的。过滤器记录的R即使在酸性状态下也保持在99%以上,即使在酸性状态下= 2020·10-6的进口H2S馏分也没有间歇洗涤。气体扩散特性与之前测试过的床层材料相当,在每米填料高度上,整个生物过滤器的低压降范围为21 – 74mm H2O。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号