首页> 外文OA文献 >Intensity-based dual model method for generation of synthetic CT images from standard T2-weighted MR images – Generalized technique for four different MR scanners
【2h】

Intensity-based dual model method for generation of synthetic CT images from standard T2-weighted MR images – Generalized technique for four different MR scanners

机译:基于强度的双模型方法,用于生成标准T2加权MR图像的合成CT图像 - 四种不同MR扫描仪的通用技术

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background and purpose: Recent studies have shown that it is possible to conduct entire radiotherapy treatment planning (RTP) workflow using only MR images. This study aims to develop a generalized intensity-based method to generate synthetic CT (sCT) images from standard T2-weighted (T2w) MR images of the pelvis. Materials and methods: This study developed a generalized dual model HU conversion method to convert standard T2w MR image intensity values to synthetic HU values, separately inside and outside of atlas-segmented bone volume contour. The method was developed and evaluated with 20 and 35 prostate cancer patients, respectively. MR images with scanning sequences in clinical use were acquired with four different MR scanners of three vendors. Results: For the generated synthetic CT (sCT) images of the 35 prostate patients, the mean (and maximal) HU differences in soft and bony tissue volumes were 16±6HUs (34HUs) and -46±56HUs (181HUs), respectively, against the true CT images. The average of the PTV mean dose difference in sCTs compared to those in true CTs was -0.6±0.4% (-1.3%). Conclusions: The study provides a generalized method for sCT creation from standard T2w images of the pelvis. The method produced clinically acceptable dose calculation results for all the included scanners and MR sequences.
机译:背景和目的:最近的研究表明,只有MR图像可以进行整个放射治疗计划(RTP)工作流程。本研究旨在开发一种基于广义的强度的方法,以产生来自骨盆的标准T2加权(T2W)MR图像的合成CT(SCT)图像。材料和方法:本研究开发了一种广义双模型HU转换方法,将标准T2W MR图像强度值转换为合成HU值,分别在地图集分段骨骼体积轮廓内外。该方法分别由20和35例前列腺癌患者进行开发和评估。利用三个供应商的四个不同MR扫描仪获得了临床用途中的扫描序列的MR图像。结果:对于35例前列腺患者的生成的合成CT(SCT)图像,柔软和骨组织体积的平均值(和最大)HU差异分别为16±6hus(34Hus)和-46±56Hus(181Hus),反对真正的CT图像。与真实CTS相比,PTV平均剂量差的平均值为-0.6±0.4%(-1.3%)。结论:该研究提供了从骨盆标准T2W图像中创建SCT的广义方法。该方法为所有包括扫描仪和MR序列产生临床上可接受的剂量计算结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号