首页> 外文OA文献 >Impact of frost temperature and moisture content on frost damage to ceramic bricks
【2h】

Impact of frost temperature and moisture content on frost damage to ceramic bricks

机译:霜水温度和水分含量对陶瓷砖的霜冻损伤的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Reliable knowledge on how frost deteriorates building materials is necessary when assessing the hygrothermal performances of building facades. Unfortunately, the current frost-thaw testing methods do not offer dependable knowledge, as they only test at very low temperatures and very high moisture contents, contrary to the spectrum of milder conditions usually met in reality. This paper therefore studies frost damage to four ceramic bricks, with accele-rated frost-thaw tests at frost temperatures from -2 °C to -20 °C and moisture saturation degrees from 0.1 to 1.0. The ultrasonic method is used to quantify the resulting frost damage, with the Young’s modulus reduction as index. The actual frost temperature and moisture content affect the level of frost damage, an effect which is not recognised however in current frost-thaw test protocols.
机译:有关如何在评估建筑物外墙的湿热性能时,需要可靠了解霜冻劣化建筑材料。不幸的是,目前的霜冻测试方法不提供可靠的知识,因为它们只在非常低的温度和非常高的水分内测试,与现实中通常会满足的频谱相反。因此,本文研究了对四个陶瓷砖的霜冻损坏,随着0.2°C至-20°C的霜温度和0.1至1.0的湿度饱和度,加速霜冻测试。超声波方法用于量化导致的霜冻损伤,随着较小的模量减少为索引。实际霜冻温度和水分含量影响霜冻损伤水平,然而,在当前霜冻测试方案中没有识别的效果。