首页> 外文OA文献 >Ceilometer aerosol profiling versus Raman lidar in the frame of the INTERACT campaign of ACTRIS
【2h】

Ceilometer aerosol profiling versus Raman lidar in the frame of the INTERACT campaign of ACTRIS

机译:在ACTRIS的INTERACT活动中,云高仪气溶胶分析与拉曼激光雷达

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Despite their differences from more advanced and more powerful lidars, thelow construction and operation cost of ceilometers (originally designed forcloud base height monitoring) has fostered their use for the quantitativestudy of aerosol properties. The large number of ceilometers availableworldwide represents a strong motivation to investigate both the extent towhich they can be used to fill in the geographical gaps between advancedlidar stations and also how their continuous data flow can be linked toexisting networks of the more advanced lidars, like EARLINET (EuropeanAerosol Research Lidar Network).In this paper, multi-wavelength Raman lidar measurements are used toinvestigate the capability of ceilometers to provide reliable informationabout atmospheric aerosol properties through the INTERACT (INTERcomparisonof Aerosol and Cloud Tracking) campaign carried out at the CNR-IMAAAtmospheric Observatory (760 m a.s.l., 40.60° N, 15.72° E), in the frameworkof the ACTRIS (Aerosol Clouds Trace gases Research InfraStructure) FP7project. This work is the first time that three different commercialceilometers with an advanced Raman lidar are compared over a period of 6 months. The comparison of the attenuated backscatter coefficient profilesfrom a multi-wavelength Raman lidar and three ceilometers (CHM15k, CS135s,CT25K) reveals differences due to the expected discrepancy in the signal to noise ratio (SNR) butalso due to changes in the ambient temperature on the short and mid-termstability of ceilometer calibration. Therefore, technological improvementsare needed to move ceilometers towards operational use in the monitoring ofatmospheric aerosols in the low and free troposphere.
机译:尽管它们与更先进,更强大的激光雷达不同,但云高仪的低廉的构建和运行成本(最初设计用于云底高度监测)却促进了其在气溶胶特性定量研究中的应用。全球范围内大量的云高仪代表着强烈的动机,既需要研究它们在多大程度上可以用来填补先进激光雷达站之间的地理空白,又要研究如何将其连续数据流与更先进的激光雷达的现有网络(如EARLINET(欧洲气溶胶研究激光雷达网络)。在本文中,多波长拉曼激光雷达测量被用于调查云高仪通过CNR-IMAAA大气观测站(INTERAR)开展的INTERACT(气溶胶与云跟踪的比较)活动提供有关大气气溶胶特性的可靠信息的能力。在ACTRIS(浮云痕量气体研究基础设施)FP7项目的框架中,海拔760 m asl,40.60°N,15.72°E。这项工作是六个月以来首次对三种带有高级拉曼激光雷达的商业偏心仪进行比较。比较多波长拉曼激光雷达和三个云高仪(CHM15k,CS135s,CT25K)的衰减后向散射系数曲线,发现差异是由于信噪比(SNR)的预期差异,也是由于环境温度的变化云高仪校准的短期和中期稳定性。因此,需要技术上的改进以使云高仪在监视对流层和自由对流层中的大气气溶胶中投入实际使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号