Background: Anthracyclines are agents with a well-known cardiotoxicity. The study sought to evaluate the hemodynamic response to an anthracycline using real-time continuous-wave (CW)-Doppler ultrasound cardiac output monitoring (USCOM) and echocardiography in combination with serum biomarkers. Methods: 50 patients (26 male, 24 female, median age 59 years) suffering from various types of cancer received an anthracycline-based regimen. Patients' responses were measured at different time points (T0 prior to infusion, T1 6 h post infusion, T2 after 1 day, T3 after 7 days, and T4 after 3 months) with CW-Doppler ultrasound (T0-T4) and echocardiography (T1, T4) for hemodynamic parameters such as stroke volume (SV; SVUSCOM ml) and ejection fraction (EF; EFechocardiography%) and with NT-pro-BNP and hs-Troponin T (T0-T4). Results: During the 3-month observation period, the relative decrease in the EF determined by echocardiography was -2.1% (Delta T0-T4, T0 71 +/- 7.8%, T4 69.5 +/- 7%, p = 0.04), whereas the decrease in SV observed using CW-Doppler was -6.5% (Delta T0-T4, T0 54 +/- 19.2 ml, T4 50.5 +/- 20.6 ml, p = 0.14). The kinetics for serum biomarkers were inversely correlated. Conclusions: Combining real-time CW-Doppler USCOM and serum biomarkers is feasible for monitoring the immediate and chronic hemodynamic changes during an anthracycline-based regimen; the results obtained were comparable to those from echocardiography.
机译:背景:蒽环类药物是具有众所周知的心脏毒性的药物。该研究试图通过实时连续波(CW)-多普勒超声心输出量监测(USCOM)和超声心动图结合血清生物标志物评估对蒽环类药物的血液动力学反应。方法:50例患有各种类型癌症的患者(男26例,女24例,中位年龄59岁)接受了蒽环类药物治疗。使用CW-多普勒超声(T0-T4)和超声心动图在不同时间点(输注前T0,输注后6小时T1,输注1天后T2、7天后T3和3个月后T4)测量患者的反应( T1,T4)的血流动力学参数,例如中风量(SV; SVUSCOM ml)和射血分数(EF;超声心动图%)以及NT-pro-BNP和hs-肌钙蛋白T(T0-T4)。结果:在3个月的观察期内,通过超声心动图测定的EF相对降低为-2.1%(Delta T0-T4,T0 71 +/- 7.8%,T4 69.5 +/- 7%,p = 0.04),而使用CW多普勒观察到的SV下降为-6.5%(Delta T0-T4,T0 54 +/- 19.2 ml,T4 50.5 +/- 20.6 ml,p = 0.14)。血清生物标志物的动力学呈负相关。结论:结合实时CW多普勒USCOM和血清生物标志物可用于监测基于蒽环类药物的治疗方案中立即和慢性的血流动力学变化。获得的结果与超声心动图可比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号