首页> 外文OA文献 >Experimental evaluation of local bond behaviour of deformed reinforcing bars in concrete structures.
【2h】

Experimental evaluation of local bond behaviour of deformed reinforcing bars in concrete structures.

机译:混凝土结构中变形钢筋局部粘结性能的实验评估。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This thesis addresses the topic of local bond behaviour in RC structures. The mechanism of bond refers to the composite action between deformed steel reinforcing bars and the surrounding concrete. Bond behaviour is an open research topic with a wide scope, particularly because bond it is such a fundamental concept to structural engineers. However, despite many bond-related research findings having wide applications, the primary contribution of this research is an experimental evaluation of the prominent features of local bond behaviour and the associated implications for the seismic performance of RC structures. The findings presented in this thesis attempt to address some structural engineering recommendations made by the Canterbury Earthquakes Royal Commission following the 2010-2011 Canterbury (New Zealand) earthquake sequence. A chapter of this thesis discusses the structural behaviour of flexure-dominated RC wall structures with an insufficient quantity of longitudinal reinforcement, among other in situ conditions, that causes material damage to predominantly occur at a single crack plane. In this particular case, the extent of concrete damage and bond deterioration adjacent to the crack plane will influence the ductility capacity that is effectively provided by the reinforcing steel. As a consequence of these in situ conditions, some lightly reinforced wall buildings in Christchurch lost their structural integrity due to brittle fracture of the longitudinal reinforcement. With these concerning post-earthquake observations in mind, there is the underlying intention that this thesis presents experimental evidence of bond behaviour that allows structural engineers to re-assess their confidence levels for the ability of lightly reinforced concrete structures to achieve the life-safety seismic performance objective the ultimate limit state.Three chapters of this thesis are devoted to the experimental work that was conducted as the main contribution of this research. Critical details of the experimental design, bond testing method and test programme are reported. The bond stress-slip relationship was studied through 75 bond pull-out tests. In order to measure the maximum local bond strength, all bond tests were carried out on deformed reinforcing bars that did not yield as the embedded bond length was relatively short. Bond test results have been presented in two separate chapters in which 48 monotonic bond tests and 27 cyclic bond tests are presented. Permutations of the experiments include the loading rate, cyclic loading history, concrete strength (25 to 70 MPa), concrete age, cover thickness, bar diameter (16 and 20 mm), embedded length, and position of the embedded bond region within the specimen (close or far away to the free surface).The parametric study showed that the concrete strength significantly influences the maximum bond strength and that it is reasonable to normalise the bond stress by the square-root of the concrete compressive strength, √(f'c). The generalised monotonic bond behaviour is described within. An important outcome of the research is that the measured bond strength and stiffness was higher than stated by the bond stress-slip relationship in the fib Model Code 2010. To account for these observed differences, an alternative model is proposed for the local monotonic bond stress-slip relationship. Cyclic bond tests showed a significant proportion of the total bond degradation occurs after the loading cycle in the peak bond strength range, which is when bond slip has exceeded 0.5 mm. Subsequent loading to constant slip values showed a linear relationship between the amount of bond strength degradation and the log of the number of cycles that were applied. To a greater extent, the cyclic bond deterioration depends on the bond slip range, regardless of whether the applied load cycling is half- or fully-reversed. The observed bond deterioration and hysteretic energy dissipated during cyclic loading was found to agree reasonably well between these cyclic tests with different loading protocols. The cyclic bond deterioration was also found to be reasonably consistent exponential damage models found in the literature.This research concluded that the deformed reinforcing bars used in NZ construction, embedded in moderate to high strength concrete, are able to develop high local bond stresses that are mobilised by a small amount of local bond slip. Although the relative rib geometry was not varied within this experimental programme, a general conclusion of this thesis is that deformed bars currently available in NZ have a relative rib bearing area that is comparatively higher than the test bars used in previous international research. From the parametric study it was found that the maximum monotonic bond strength is significant enhanced by dynamic loading rates. Experimental evidence of high bond strength and initial bond stiffness generally suggests that only a small amount of local bond slip that can occur when the deformed test bar was subjected to large tension forces. Minimal bond slip and bond damage limits the effective yielding length that is available for the reinforcing steel to distribute inelastic material strains. Consequently, the potential for brittle fracture of the reinforcement may be a more problematic and widespread issue than is apparent to structural engineers. This research has provided information that improve the reliability of engineering predictions (with respect to ductility capacity) of maximum crack widths and the extent of bond deterioration that might occur in RC structures during seismic actions.
机译:本文讨论了钢筋混凝土结构中的局部键行为。粘结机理是指变形的钢筋与周围混凝土之间的复合作用。粘结行为是一个广泛的开放性研究主题,特别是因为粘结对于结构工程师而言是一个基本概念。然而,尽管许多与粘结有关的研究发现得到了广泛的应用,但这项研究的主要贡献是对局部粘结行为的突出特征以及对RC结构的抗震性能的相关影响进行了实验评估。本文提出的发现试图解决2010年至2011年坎特伯雷(新西兰)地震序列后坎特伯雷地震皇家委员会提出的一些结构工程建议。本文的一章讨论了以弯曲为主的钢筋混凝土墙结构的结构行为,该结构的纵向钢筋数量不足,在其他原位条件下,其主要在单个裂缝平面上引起材料破坏。在这种特殊情况下,靠近裂缝平面的混凝土损坏和粘结劣化的程度将影响由钢筋有效提供的延展性。这些原位条件的结果是,由于纵向钢筋的脆性断裂,克赖斯特彻奇的一些轻度加固的墙体建筑失去了结构完整性。考虑到这些与地震后有关的观察结果,其潜在目的是,本文提出结合行为的实验证据,使结构工程师可以重新评估其对轻型钢筋混凝土结构实现生命安全地震响应能力的置信度。性能目标是极限状态。本论文分为三章进行实验研究,作为本研究的主要贡献。报告了实验设计,粘结测试方法和测试程序的关键细节。通过75个粘结拉拔试验研究了粘结应力-滑动关系。为了测量最大的局部粘结强度,所有的粘结试验都是在变形的钢筋上进行的,由于埋入的粘结长度相对较短,钢筋没有屈服。在两个单独的章节中介绍了键测试结果,其中分别介绍了48个单调键测试和27个循环键测试。实验的排列包括加载速率,循环加载历史,混凝土强度(25至70 MPa),混凝土年龄,覆盖层厚度,钢筋直径(16和20 mm),埋入长度以及样品中埋入粘结区域的位置参数研究表明,混凝土强度显着影响最大粘结强度,合理的是用混凝土抗压强度的平方根√(f' C)。其中描述了广义的单调键行为。该研究的重要结果是,所测得的粘结强度和刚度高于fib模型代码2010中的粘结应力-滑动关系所规定的值。为解决这些观察到的差异,针对局部单调粘结应力提出了另一种模型滑关系。循环粘结测试显示,在峰值粘结强度范围内(即粘结滑移超过0.5 mm时),在加载周期后发生的总粘结降解中有很大比例。随后的载荷达到恒定的滑移值,表明粘结强度下降的幅度与所施加循环次数的对数之间呈线性关系。循环粘结的劣化在更大程度上取决于粘结滑移范围,而不管所施加的载荷循环是反向还是完全反向。发现在循环加载期间观察到的键变差和耗散的滞后能量在具有不同加载方案的这些循环测试之间相当吻合。循环粘结变质也被认为是文献中发现的合理一致的指数损伤模型。该研究得出的结论是,NZ建筑中使用的变形钢筋嵌入中高强度混凝土中,能够产生较高的局部粘结应力。由少量的本地债券单据动员。尽管在此实验程序中相对肋的几何形状没有变化,该论文的一般结论是,目前在新西兰可获得的变形钢筋的相对肋骨承载面积比以前的国际研究中使用的试验钢筋高。从参数研究中发现,最大单调粘结强度通过动态加载速率显着提高。高粘结强度和初始粘结刚度的实验证据通常表明,在变形的测试棒承受较大拉力时,只会发生少量的局部粘结滑移。最小的粘结滑移和粘结破坏限制了有效屈服长度,有效屈服长度可用于钢筋分配非弹性材料应变。因此,与结构工程师相比,钢筋脆性断裂的可能性可能是一个问题更大,分布更广泛的问题。这项研究提供的信息可提高最大裂缝宽度的工程预测(相对于延性能力)的可靠性以及地震作用期间RC结构中可能发生的粘结劣化程度。

著录项

  • 作者

    Morris Gareth John;

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号