首页> 外文OA文献 >A simple C-14-respirometric method for assessing microbial catabolic potential and contaminant bioavailability.
【2h】

A simple C-14-respirometric method for assessing microbial catabolic potential and contaminant bioavailability.

机译:一种简单的C-14呼吸测定法,用于评估微生物的分解代谢潜能和污染物的生物利用度。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This paper describes the validation and application of a simple flask-based C-14-respirometer system designed to assess mineralisation of C-14-labelled substrates under defined conditions. Validation of this respirometer system indicated stoichiometric CO2 trapping up to a maximum of 400 mu mol of CO2 tin a single trap). Polycyclic aromatic hydrocarbon (PAH)-degrading bacteria were used to measure growth-linked biodegradation of [C-14]naphthalene to (CO2)-C-14. A C-14 activity balance of 101.7 +/- 8.9% (n = 6), after 74 h incubation time and 10 respirometer-opening events, indicated the suitability of the system for monitoring substrate mineralisation. This respirometric apparatus was then successfully applied to assess: (i) the PAH catabolism of microbes in a field contaminated soil, where naphthalene and phenanthrene were rapidly mineralised and (ii) soil-associated organic contaminant bioavailability, where increased soil-phenanthrene contact time resulted in a reduction in phenanthrene mineralisation in the soil. The described respirometer system differs from existing respirometer systems in that the CO2 trap can be removed and replaced quickly and easily. The system is efficient, reproducible, adaptable to many situations, easy to construct and simple to use, it therefore affords advantages over existing systems. (C) 2001 Federation of European Microbiological Societies. Published by Elsevier Science B.V. All rights reserved.}
机译:本文介绍了一个简单的基于烧瓶的C-14呼吸仪系统的验证和应用,该系统旨在评估在限定条件下C-14标记的底物的矿化程度。对该呼吸计系统的验证表明,化学计量的二氧化碳捕集(单个捕集阱最多可捕集最多400摩尔mol的二氧化碳)。使用多环芳香烃(PAH)降解细菌来测量[C-14]萘与(CO2)-C-14的生长相关生物降解。经过74小时的培养时间和10次呼吸计开启事件后,C-14活性平衡为101.7 +/- 8.9%(n = 6),表明该系统适用于监测底物矿化。该呼吸测定仪随后成功地用于评估:(i)田间污染土壤中微生物的PAH分解代谢,其中萘和菲被快速矿化;(ii)与土壤相关的有机污染物的生物利用度,导致土壤与菲的接触时间增加减少了土壤中菲的矿化。所描述的呼吸计系统与现有的呼吸计系统的不同之处在于,可以轻松快捷地移除和更换CO2捕集阱。该系统高效,可重现,适应多种情况,易于构建且易于使用,因此与现有系统相比具有优势。 (C)2001年欧洲微生物学会联合会。由Elsevier Science B.V.出版。保留所有权利。}

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号