首页> 美国政府科技报告 >Health Hazard Evaluation Report: HETA-2013-0145-3209, May 2014. Evaluation of Environmental Controls at a Homeless Shelter Associated with a Tuberculosis Outbreak - Texas.
【24h】

Health Hazard Evaluation Report: HETA-2013-0145-3209, May 2014. Evaluation of Environmental Controls at a Homeless Shelter Associated with a Tuberculosis Outbreak - Texas.

机译:健康危害评估报告:HETa-2013-0145-3209,2014年5月。评估与结核病爆发相关的无家可归者收容所的环境控制 - 德克萨斯州。

获取原文

摘要

On May 22, 2013, the National Institute for Occupational Safety and Health (NIOSH) received a request for technical assistance from the shelter manager at a large homeless shelter in Dallas, Texas, linked to an ongoing tuberculosis outbreak. The request asked NIOSH to assess the heating, ventilation, and air-conditioning (HVAC) systems and make recommendations to improve overall environmental controls at the shelter. During an on-site evaluation of the homeless shelter in June 2013, we collected physical and ventilation measurements in all key areas of the facility. We focused on areas where shelter guests typically congregate or spend significant amounts of time. We recorded the make and model number of all air-handling units (AHUs) providing air to the facility, and visually inspected the units. When possible, we measured the air flow rate through supply diffusers and return grilles. The AHUs in place were state-of-the-art and were controlled by a modern building automation system. The ventilation systems were well maintained and functional during our visit, and all AHUs were equipped with proper filter configurations. Despite their excellent condition and maintenance, certain aspects of the ventilation systems' operation could potentially contribute to airborne disease transmission among shelter guests. During our visit, it appeared the AHUs were not providing adequate outdoor air to the occupied spaces under certain occupancy and environmental conditions, as is required by the Dallas Mechanical Code and ASHRAE standards. In addition to alleviating odors and maintaining occupant comfort, outdoor air serves to dilute infectious aerosols, such as Mycobacterium tuberculosis droplet nuclei that are responsible for TB transmission. Since the TB outbreak began, the shelter has taken numerous steps to improve administrative controls, particularly when it comes to identifying guests showing signs and symptoms of TB. We recommend additional improvements to the administrative and environmental controls at the shelter. From a ventilation standpoint, we suggest that all occupied spaces at the shelter complex be supplied adequate amounts of outdoor air, as prescribed by the Dallas Mechanical Code and ASHRAE standards.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号