首页> 美国政府科技报告 >Miniature Bilevel Alarm for Oxygen-Deficient Atmospheres
【24h】

Miniature Bilevel Alarm for Oxygen-Deficient Atmospheres

机译:适用于缺氧环境的微型双层报警器

获取原文

摘要

The Bureau of Mines has developed a miniature, portable two-level oxygen-deficiency alarm and produced three prototype models. Each operates from a 4.2-v dc power source, and the highest current drain of any model is 80 ma. An electrochemical cell, which produces an electrical output in proportion to the partial pressure of oxygen to which it is exposed, is used as an oxygen detector. The output of the cell is applied to an electronic circuit that detects two different levels of oxygen percentage below that of normal air, and produces distinct audible signals at these levels. The hazard alarm mode is activated when the oxygen percentage first drops below normal and produces a 500-cps 'beep' tone with an intermittency of 1 cps. The danger mode produces a continuous 500-cps audible signal when the oxygen percentage drops still lower. (Author)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号