首页> 美国政府科技报告 >Determination of Lead and Cadmium in Fish and Clam Tissue by Atomic Absorption Spectrometry with a Molybdenum and Lanthanum Treated Pyrolytic Graphite Atomizer
【24h】

Determination of Lead and Cadmium in Fish and Clam Tissue by Atomic Absorption Spectrometry with a Molybdenum and Lanthanum Treated Pyrolytic Graphite Atomizer

机译:钼镧处理热解石墨雾化原子吸收光谱法测定鱼和蛤蜊组织中的铅和镉

获取原文

摘要

A molybdenum and lanthanum treated pyrolytically coated graphite tube is employed for the furnace atomic absorption spectrometric determination of lead and cadmium directly in nitric-perchloric acid tissue digests. Lanthanum tends to promote the formation of a smooth lead atomization peak for aid in peak quantitation. Both molybdenum and lanthanum help reduce chemical interference and interference from uncompensated background signals during analyte atomization. Under typical conditions, the average analytical recoveries are within the 90-110% range for both lead and cadmium, and peak height reproducibility is about 2-3% when working sufficiently above detection limits. Accuracy of the method is assessed by analyzing the NBS SRM 1577 bovine liver standard and performing alternate determinations by anodic stripping voltammetry.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号