首页> 美国政府科技报告 >Development of In-Situ Techniques for the Detection and Measurements of Corrosion of Copper Concentric Neutrals in Underground Environments
【24h】

Development of In-Situ Techniques for the Detection and Measurements of Corrosion of Copper Concentric Neutrals in Underground Environments

机译:地下环境中铜同心中性腐蚀检测与测量的现场技术研究进展

获取原文

摘要

The titles of the papers included are: (1) Final Technical Report on the Development of In-Situ Techniques...Underground Environments; (2) Electrochemical and Corrosion Studies on Copper Concentric Neutral Wires; (3) Laboratory Corrosion Studies on Tinned Copper Concentric Neutral Wires; (4) Corrosion Induced by an Alternating Voltage. A Comparison Between Theoretical Predictions and Experimental Results; (5) Detection and Analysis of Electrochemical Noise for Corrosion Studies; (6) Applications of a Low-Noise Potentiostat in Electrochemical Measurements; (7) A Low-Noise Potentiostat for the Study of Small Amplitude Signals in Electrochemistry; (8) Corrosion Enhancement Due to Large Voltage Modulations. Frequency Analysis of the Response of Electrodes Under Charge-Transfer Control; (9) Studies of Passive Film Breakdown by Detection and Analysis of Electrochemical Noise; (10) A Field Study on the Corrosion of Concentric Neutral Cable; (11) AC Induced Corrosion. The Effect of an Alternation Voltage on Electrodes Under Charge-Transfer Control.