首页> 美国政府科技报告 >Possible Safety Hazards Associated with the Operation of the 0.3-M Transonic Cryogenic Tunnel at the NASA Langley Research Center
【24h】

Possible Safety Hazards Associated with the Operation of the 0.3-M Transonic Cryogenic Tunnel at the NASA Langley Research Center

机译:与美国宇航局兰利研究中心0.3米超声波低温隧道运行相关的安全隐患

获取原文

摘要

The 0.3 m Transonic Cryogenic Tunnel (TCT) at the NASA Langley Research Center was built in 1973 as a facility intended to be used for no more than 60 hours in order to verify the validity of the cryogenic wind tunnel concept at transonic speeds. The role of the 0.3 m TCT has gradually changed until now, after over 3000 hours of operation, it is classified as a major NASA research facility and, under the administration of the Experimental Techniques Branch, it is used extensively for the testing of airfoils at high Reynolds numbers and for the development of various technologies related to the efficient operation and use of cryogenic wind tunnels. The purpose of this report is to document the results of a recent safety analysis of the 0.3 m TCT facility. This analysis was made as part of an on going program with the Experimental Techniques Branch designed to ensure that the existing equipment and current operating procedures of the 0.3 m TCT facility are acceptable in terms of today's standards of safety for cryogenic systems.