首页> 美国政府科技报告 >Instrumented Impact Testing Machine with Reduced Specimen Oscillation Effects
【24h】

Instrumented Impact Testing Machine with Reduced Specimen Oscillation Effects

机译:具有降低的试样振荡效应的仪表式冲击试验机

获取原文

摘要

A pendulum-type instrumented Charpy test apparatus based on inverted test geometry was developed. Geometry inversion reduces inertia load and specimen oscillation effects. Initial impact energy is double that of standard (300 J) impact testers, allowing the use of larger (10 x 20 x 110 mm) bend specimens than normal Charpy specimens. The rotation axis in the three point bending is nearly stationary, making COD-measurements possible. Inertia effects and specimen oscillations are compared with the conventional tester, and using an analytical finite element model for Charpy V-notch specimens. Better performance for the inverted geometry is reported.