首页> 美国政府科技报告 >Dynamic response for thermal control and measurement and fast radiation thermometry
【24h】

Dynamic response for thermal control and measurement and fast radiation thermometry

机译:热控制和测量以及快速辐射测温的动态响应

获取原文

摘要

A preliminary evaluation was made by ORNL of a two-color ratio pyrometer (TCRP) for temperature control in the Modular Electromagnetic Levitation (MEL) experiment. A discussion was presented by Eric Spjut at the 1987 NASA Non-Contact Temperature Measurement Workshop (NASA Conf. Publ. 2503, pp. 182-213) in which he described the non-linear characteristics of the time response of TCPs. Researchers replicated his model and results and note that the non-linear response behavior is minimized for small temperature steps at high temperatures. They then used the predicted response in a model for a proportional or integral feedback controller and predicted the control characteristics for heating and cooling a 5-mm diameter sphere of niobium at high (1500 to 2750 K) temperatures. The analysis shows that for a slow (25-ms) time response for a commercial RCRP, overshoots of several hundred kelvins will result from a 100-K decrease in the setpoint, and temperature tracking errors of 14 to 45 K will occur for control temperature ramps of 1000K/s. For a fast (greater than 0.1 ms) time response, the overshoot and ramp response errors are largely eliminated.

著录项