首页> 美国政府科技报告 >Investigation of the Flow-Induced Vibration in the E2 Test Facility
【24h】

Investigation of the Flow-Induced Vibration in the E2 Test Facility

机译:E2试验装置内流动引起的振动研究

获取原文

摘要

An investigation of flow induced vibration due to coupling between the fluid flow and the propellants lines (LOX and RP-1) was performed. Various flow rate conditions were studied to check whether flow induced vibration was possible due to vortex shedding in both valves and pipe lines. Resonance test was conducted for all segments of the LOX-feedline for the preburner under test. In addition, critical values of frequency and velocity are calculated using a mass damping model. A simple chart characterizing the relation between frequency and velocity is developed for each component; i.e. propellant lines, valves and flow meters. It was found that flow induced vibration occurs for various segments with flow rates of 113 lb/s, 275 lb/s and 40 lb/s. Even more interesting using critical conditions for buckling, it was found that the valve or pipe may collapse for a flow rate of 275 lb/s and valve height of 10% of pipe diameter. Furthermore, two models for the acoustic pressure acting on the segments particularly for the valve are proposed.