首页> 美国政府科技报告 >Component performance investigation of J71 experimental turbine. IV-Effect of first-stator adjustment; over-all performance of J71-97 turbine with 132-percent-design stator area
【24h】

Component performance investigation of J71 experimental turbine. IV-Effect of first-stator adjustment; over-all performance of J71-97 turbine with 132-percent-design stator area

机译:J71实验涡轮机组件性能研究。 IV-第一次定子调整的影响; J71-97涡轮机的总体性能,定子面积设计为132%

获取原文

摘要

An experimental invesitgation of the effect of increasing the first-stator area of the J71-97 experimental three-stage turbine from 97 percent of design to 132 percent revealed (1) the maximum efficiency obtained decreased from 0.891 to 0.869, (2) the choking equivalent weight flows increased by approximately 13.6 percent, and (3) at the turbine match points required to maintain the compressor at constant design equivalent conditions the turbine efficiency decreased from 0.87 to 0.86.