首页> 美国政府科技报告 >Instruction Manual for ANL Passive Acoustic Flow Measurement System
【24h】

Instruction Manual for ANL Passive Acoustic Flow Measurement System

机译:aNL无源声流测量系统使用说明书

获取原文

摘要

The ANL Passive Acoustic Flow Measurement System is a signal processor designed to measure the flow rate of particles suspended in a gas. The intended application is the measurement of char flow at the BI-GAS Pilot Plant, Homer City, PA. An undetected flow stoppage can very quickly cause a dangerous temperature excursion in the gasifier. At the request of BI-GAS, Argonne National Laboratory (ANL) has developed and installed acoustic monitors which give rapid indications of blockages or other flow perturbations in the char lines. These monitors use a high temperature microphone for measuring the acoustic attenuation caused by the presence of char in the lines. This manual describes the components and gives instructions for installation and operation of the system. Figure 1 shows the components of the flow measurement system. Detailed discussion of the principle of operation and design of the flow monitor may be found in Technical Memorandum An Acoustic Char Flow Monitor for the BI-GAS Pilot Plant, ANL-FE-49622-TM08, July 1979. (ERA citation 05:014633)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号