首页> 美国政府科技报告 >Testing and Evaluation of Advanced Lead-Acid Batteries for Utility Load-Leveling Applications
【24h】

Testing and Evaluation of Advanced Lead-Acid Batteries for Utility Load-Leveling Applications

机译:用于公用负载水平应用的先进铅酸蓄电池的测试和评估

获取原文

摘要

Testing and evaluation of advanced lead-acid batteries developed by Exide for utility load-leveling applications have been conducted at Argonne National Laboratory's National Battery Test Laboratory since April 1982. These batteries (36-kWh and 18-kWh modules) have a projected life of greater than 4000 deep discharge cycles. This paper describes results obtained to date from the test program. Parametric test results and general performance observations for these batteries are reported. (ERA citation 08:041226)