首页> 美国政府科技报告 >Aerosol Sampling: Comparison of Two Rotating Impactors for Field Droplet Sizing and Volumetric Measurements
【24h】

Aerosol Sampling: Comparison of Two Rotating Impactors for Field Droplet Sizing and Volumetric Measurements

机译:气溶胶取样:两种旋转冲击器的比较,用于场滴尺寸和体积测量

获取原文

摘要

This article compares the collection characteristics of a new rotating impactor Florida Latham Bonds (FLB) sampler for ultrafine aerosols with a mimic of the industry standard (Hock-type). The volume and droplet-size distribution collected by the rotating impactors were measured via spectroscopy and microscopy. The rotary impactors were colocated with an isokinetic air sampler for a total volume flux measurement and a laser diffraction instrument for droplet-size distribution measurement. The measured volumetric flux and droplet-size distribution collection efficiencies were compared across 3 wind speeds (1, 1.8, and 3.5 m/sec). The FLB sampler had higher flux collection efficiencies than the Hock-type sampler. The FLB sampler collected 89%, 87%, and 98% of the total volume available per unit area at 1, 1.8, and 3.5 m/sec, respectively, whereas the Hock-type sampler collected 68%, 19%, and 21% of across the same wind speeds. Changes in wind speed had less impact and resulted in less data variability for the FLB sampler.