首页> 美国政府科技报告 >TESTS ON THE AIR FLOW THROUGH A CENTRIFUGAL IMPELLER
【24h】

TESTS ON THE AIR FLOW THROUGH A CENTRIFUGAL IMPELLER

机译:通过离心叶轮测试空气流量

获取原文

摘要

Test results on the use of hot wire anemometers to measure the relative flow, inside and outside the vane passages of a centrifugal impeller are given. Provided that the flow sense does not fluctuate the results appear to be reliable to within 5% or so. The measured velocity pattern in this impeller is not in agreement with that suggested by the usual theories of the flow in centrifugal impellers. The present impeller which was designed for a fan does not conform to pump practice and better results may be obtained with an impeller with smaller vane angles.

著录项

  • 作者

    R. W. Worster;

  • 作者单位
  • 年度 1954
  • 页码 1-21
  • 总页数 21
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 工业技术;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号