首页> 美国政府科技报告 >Experimental Evaluation of Environmental Control Systems for Closed Shelters
【24h】

Experimental Evaluation of Environmental Control Systems for Closed Shelters

机译:封闭式避难所环境控制系统的实验评价

获取原文

摘要

This report summarizes results of an experimental study of 0 supply and CO2 control systems suitable for use in closed shelters for protection against fallout and/or other weapons effects. The program objectives included: (1) determination of performance characteristics and design requirements for passive CO2 absorption techniques, (2) verification of the state-of-the-art design data for dynamic CO2 absorption systems, and(3) evaluation of O commercially available regulators to determine possible design changes to provide apparatus that is more suitable for use in closed shelters. Thirty-six simulated occupany tests and one human occupancy test were conducted in order to evaluate passive CO2 absorption methods. Two canister tests were conducted to verify the design data for dynamic CO2 absorption methods. Fifteen regulator manufacturers were contracted in the field of survey effort. The program results (for a 24-hr. closure period) are as follows: (1) O supply can be provided at a cost of about $4.70 per person for smaller shelters (100-man) or about $4.15 per person in larger shelters (1000-man), and (2) CO2 concentration can be controlled satisfactorily by the use of Baralyme (or soda-lime at a slight loss in efficiency) in screened panels at a cost of about $4.50 per person. (Author)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有