首页> 美国政府科技报告 >Feasibility of Detecting Corrosion in Electric Fuzes Using the Thermal TransientTechnique
【24h】

Feasibility of Detecting Corrosion in Electric Fuzes Using the Thermal TransientTechnique

机译:利用热瞬态技术检测电引信腐蚀的可行性

获取原文

摘要

The object of this experiment was to determine if the thermal transient test canbe used to detect corrosion on the bridgewire in an electric fuze or electroexplosive device (EED). The fuzes are used to set self-destruct times in the following mines: M74, M75, BLU-92/B. When the mines are exposed to high humidity the bridgewire inside the fuze is susceptible to corrosion. An open (corroded) fuze may initiate the wrong self-destruct time which in turn will create a hazardous condition for friendly troops. Two examples of severe corrosion of the bridgewire in a fuze are shown in figures 3 and 4. These photographs were taken by a scanning electron microscope. The current method for detecting corrosion in a fuze is measuring the cold resistance of the bridgewire. A high resistance reading indicates evidence of corrosion. It will be determined if the thermal transient test can be used as an alternative method. The thermal transient test is a nondestructive examination technique for inspection of the critical bridgewire interface. The test allows one to see inside the fuze non-destructively and determine if certain failure conditions or abnormalities are present. (aw)