...
首页> 外文期刊>Physiological measurement >Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions
【24h】

Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions

机译:光电容积脉搏波脉搏率变异性作为非平稳状态下心率变异性的替代指标

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this paper we assessed the possibility of using the pulse rate variability (PRV) extracted from the photoplethysmography signal as an alternative measurement of the HRV signal in non-stationary conditions. The study is based on analysis of the changes observed during a tilt table test in the heart rate modulation of 17 young subjects. First, the classical indices of HRV analysis were compared to the indices from PRV in intervals where stationarity was assumed. Second, the time-varying spectral properties of both signals were compared by time-frequency (TF) and TF coherence analysis. Third, the effect of replacing PRV with HRV in the assessment of the changes of the autonomic modulation of the heart rate was considered. Time-invariant HRV and PRV indices showed no statistically significant differences (p > 0.05) and high correlation (>0.97). Time-frequency analysis revealed that the TF spectra of both signals were highly correlated (0.99 +/- 0.01); the difference between the instantaneous power, in the LF and HF bands, obtained from HRV and PRV was small (<10(-3) s(-2)) and their temporal patterns were highly correlated (0.98 +/- 0.04 and 0.95 +/- 0.06 in the LF and HF bands, respectively) and TF coherence in the LF and HF bands was high (0.97 +/- 0.04 and 0.89 +/- 0.08, respectively). Finally, the instantaneous power in the LF band was observed to significantly increase during head-up tilt by both HRV and PRV analysis. These results suggest that although some differences in the time-varying spectral indices extracted from HRV and PRV exist, mainly in the HF band associated with respiration, PRV could be used as a surrogate of HRV during non-stationary conditions, at least during the tilt table test.
机译:在本文中,我们评估了使用从光电容积描记术信号中提取的脉搏率变异性(PRV)作为非平稳条件下HRV信号的替代方法的可能性。这项研究是基于对倾斜表测试期间对17位年轻受试者进行心率调节所观察到的变化的分析。首先,在假设平稳的时间间隔内,将HRV分析的经典指标与PRV的指标进行比较。其次,通过时频(TF)和TF相干分析比较了两个信号的时变频谱特性。第三,考虑了用HRV替代PRV在评估心律自主调节变化方面的作用。时变HRV和PRV指数无统计学差异(p> 0.05)和高度相关(> 0.97)。时频分析显示两个信号的TF光谱高度相关(0.99 +/- 0.01);从HRV和PRV获得的LF和HF频带中的瞬时功率之间的差异很小(<10(-3)s(-2)),并且它们的时间模式高度相关(0.98 +/- 0.04和0.95 +分别在LF和HF频带中为0.06)和LF和HF频带中的TF相干性很高(分别为0.97 +/- 0.04和0.89 +/- 0.08)。最后,通过HRV和PRV分析,在抬头倾斜期间,可以观察到LF频段的瞬时功率显着增加。这些结果表明,尽管从HRV和PRV提取的随时间变化的光谱指数存在一些差异,主要在与呼吸有关的HF波段,但PRV可以用作非平稳条件下(至少在倾斜期间)的HRV替代表测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号