An 82-year-old man with asthma and chronic obstructive pulmonary disease experienced sudden back pain. Chest computed tomography (CT) showed a thoracic aortic aneurysm (TAA) 63mm in maximum diameter, with severe atheromas, representing "shaggy aorta", extending down to the level of the ninth thoracic vertebra. Emergency surgery was necessitated by the impending rupture of the aneurysm. The patient underwent successful total arch replacement with open-stent grafting using a GORE? TAG? thoracic endoprosthesis. His postoperative course was uneventful and there were no neurological complications. We discuss the advantages and disadvantages of using the GORE TAG system for an open-stent graft.
机译:一名患有哮喘和慢性阻塞性肺疾病的82岁男子突然背痛。胸部计算机断层扫描(CT)显示最大直径为63mm的胸主动脉瘤(TAA),伴有严重的动脉瘤,代表“毛茸茸的主动脉”,延伸至第九胸椎水平。即将发生的动脉瘤破裂需要紧急手术。患者使用GORE?成功进行了全弓置换,并采用开放支架移植术。标签?胸腔内假体。术后过程平稳,无神经系统并发症。我们讨论了将GORE TAG系统用于开放式支架移植的优缺点。