首页> 外文期刊>Osteoporosis international: a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA >Comparison of quantitative ultrasound of the phalanges with conventional bone densitometry in healthy postmenopausal women.
【24h】

Comparison of quantitative ultrasound of the phalanges with conventional bone densitometry in healthy postmenopausal women.

机译:健康绝经后妇女指骨定量超声与常规骨密度测定的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of this study was to evaluate the utility of the quantitative ultrasound (QUS) technique for the identification of subjects with spine fracture or low bone mineral density (BMD) previously determined by dual energy X-ray absorptiometry (DEXA). QUS of the phalanges in 1,350 postmenopausal women (60-83 years old) was compared with DEXA measurements of four skeletal sites (lumbar spine, total hip, femoral neck, and distal radius) of the same subjects. The contribution of body mass index (BMI) was also assessed. Amplitude dependent speed of sound (AD-SoS), ultrasound bone profile index (UBPI), and BMD of all anatomical regions, except for the spine, decreased significantly with increasing age quartiles. QUS parameters correlated weakly but significantly with BMD ( r =0.21-0.31, p <0.01). After adjustment for BMI, the association between QUS parameters and BMD remained unchanged. UBPI was found to be independent of BMI. All techniques and all sites were able to significantly discriminate fractured from non-fractured subjects by receiver operating characteristic (ROC) analysis (area under the curve [AUC]> or =0.60, p <0.0001). AD-SoS and UBPI showed similar fracture discrimination ability of spine, distal radius and total body BMD in terms of odds ratios, but BMD of the total hip and femoral neck showed the best performance in discriminating fractured from non-fractured subjects. In conclusion, QUS assessment of the phalanges correlates moderately with BMD of all skeletal sites and is able to effectively discriminate fractured from non-fractured subjects.
机译:这项研究的目的是评估定量超声(QUS)技术在鉴定先前通过双能X射线吸收法(DEXA)确定的脊柱骨折或低骨密度(BMD)受试者中的实用性。将1,350名绝经后妇女(60-83岁)的指骨的QUS与相同受试者的四个骨骼部位(腰椎,全髋,股骨颈和distal骨远端)的DEXA测量值进行比较。还评估了体重指数(BMI)的贡献。随着年龄的四分位数的增加,除脊柱外,所有解剖区域的振幅依赖的声速(AD-SoS),超声骨轮廓指数(UBPI)和BMD均显着降低。 QUS参数与BMD弱相关但显着相关(r = 0.21-0.31,p <0.01)。调整BMI后,QUS参数和BMD之间的关联保持不变。发现UBPI独立于BMI。通过接受者操作特征(ROC)分析(曲线下面积[AUC]>或= 0.60,p <0.0001),所有技术和所有部位均能够明显地区分未破裂受试者。就优势比而言,AD-SoS和UBPI显示出相似的脊柱,远端distal骨和全身BMD骨折识别能力,但整个髋部和股骨颈的BMD在区分骨折与未骨折的受试者方面表现出最好的表现。总之,对趾骨的QUS评估与所有骨骼部位的BMD适度相关,并且能够有效地区分骨折患者和未骨折患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号