Introduction: This systematic review aims to summarize the procedural arrhythmia termination rates in catheter ablation (CA) procedures of atrial or ventricular arrhythmias using the commonly used mapping systems (CARTO, Rhythmia and EnSite/NavX). Materials and Methods: A systematic search in MEDLINE and Cochrane databases through February 2021 was performed. Results: With regard to atrial fibrillation ablation procedures, acute success rates ranged from 15.4 to 96.0 and 9.1 to 100.0 using the CARTO and EnSite/NavX mapping systems, respectively; acute atrial tachycardia (AT) termination to sinus rhythm ranged from 75 to 100 using the CARTO system. The acute success rate for different types of AT ranged from 75 to 97 using Rhythmia, while the NavX mapping system was also found to have excellent efficacy in the setting of AT, with acute arrhythmia termination rates ranging from 73 to 99. With regard to ventricular tachycardia, in the setting of ischaemic cardiomyopathy, acute success rates ranged from 70 to 100 using CARTO and 64 using EnSite/NavX systems. The acute success rate using the Rhythmia system ranged from 61.5 to 100.0 for different clinical settings. Conclusions: Mapping systems have played a crucial role in high-density mapping and the observed high procedural success rates of atrial and ventricular CA procedures. More data are needed for the comparative efficacy of mapping systems in acute arrhythmia termination, across different clinical settings.
机译:简介:本系统综述旨在总结使用常用标测系统 (CARTO、Rhythmia 和 EnSite/NavX) 的房性或室性心律失常导管消融 (CA) 手术中的程序性心律失常终止率。材料和方法: 在 MEDLINE 和 Cochrane 数据库中进行了截至 2021 年 2 月的系统检索。结果: 关于心房颤动消融手术,使用 CARTO 和 EnSite/NavX 标测系统的急性成功率分别为 15.4% 至 96.0% 和 9.1% 至 100.0%;使用 CARTO 系统时,急性房性心动过速 (AT) 终止为窦性心律的发生率为 75% 至 100%。使用 Rhythmia 对不同类型 AT 的急性成功率为 75% 至 97%,同时还发现 NavX 标测系统在 AT 的情况下具有出色的疗效,急性心律失常终止率为 73% 至 99%。关于室性心动过速,在缺血性心肌病的情况下,使用 CARTO 的急性成功率为 70% 至 100%,使用 EnSite/NavX 系统的急性成功率为 64%。对于不同的临床环境,使用 Rhythmia 系统的急性成功率在 61.5% 到 100.0% 之间。结论:标测系统在高密度标测和观察到的心房和心室 CA 手术的高手术成功率中发挥了至关重要的作用。需要更多数据来比较标测系统在不同临床环境中终止急性心律失常的疗效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号