BACKGROUND: Vascular injury during laparoscopic surgery typically occurs with the blind insertion of either the Veress needle or the trocar. We report an aortic puncture from the use of a laparoscopic fascial closure device. CASE: After a laparoscopic-assisted vaginal hysterectomy and during closure of the 10-mm umbilical port with a fascial closure device, attempted passage of the needle encountered unusual resistance in the abdominal wall. Application of increased force resulted in uncontrolled entry of the needle into the abdominal cavity and a 1-mm puncture of the aorta. After emergency laparotomy the puncture was successfully repaired by a vascular surgeon. CONCLUSION: A previously unreported complication of this laparoscopic fascial closure device is aortic injury. Unusual resistance to passage of the needle should engender extra caution. The use of assistive closure devices should be reserved for patients with difficult anatomy.
机译:背景:腹腔镜手术期间的血管损伤通常发生于Veress针或套管针的盲插入。我们报告通过使用腹腔镜筋膜封闭装置的主动脉穿刺。案例:腹腔镜辅助阴道子宫切除术后,在使用筋膜闭合装置闭合10毫米脐带口期间,尝试穿刺的针头在腹壁遇到异常阻力。施加更大的力会导致针头不受控制地进入腹腔,并且主动脉被刺穿1毫米。紧急剖腹手术后,血管外科医师成功修复了穿刺。结论:这种腹腔镜筋膜闭合装置先前未曾报道的并发症是主动脉损伤。异常的针头穿刺阻力应引起特别注意。解剖困难的患者应使用辅助闭合装置。