Optimization of the sensitivity and stability of the PRESAGE? dosimeter using trihalomethane radical initiators

机译:优化PRESAGE的灵敏度和稳定性?使用三卤甲烷自由基引发剂的剂量计

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study is to investigate the effect of trihalomethane radical initiators on the radiological properties, radiation dose sensitivity and post response photo-stability of the PRESAGE dosimeter. Different PRESAGE dosimeters containing 50 and 100 mM of iodoform (CHI3), bromoform (CHBr3) or chloroform (CHl3) radical initiators where fabricated and irradiated with 6 MV photons for a range of radiation doses from 0 to 30 Gy. A comparison between sensitivity and radiological properties of the PRESAGE dosimeters with the different radical initiators was carried out. Optical density changes of the dosimeters before and after irradiation were measured using a spectrophotometer. The incorporation of different radical initiators in the composition of the PRESAGE dosimeter resulted in variation of the radiation dose sensitivity and radiological properties of the dosimeters depending on the type and concentration of the radical initiator used, with iodoform showing the highest dose-response slope followed by bromoform and chloroform. However, at 100 mM iodoform, the effective atomic number was significantly higher than water (Z_(eff)=16). This enhancement in dose-response was found to be directly related to the carbon-halogen bond dissociation energy and to the radiological properties of each individual radical initiator used in this study. Furthermore, the post-response stability of the PRESAGE dosimeters over two weeks remained stable regardless of the trihalomethane radical initiator employed, with negligible change in the post-response stability and linearity of the PRESAGE dosimeters.
机译:这项研究的目的是研究三卤甲烷自由基引发剂对PRESAGE剂量计的放射学性质,辐射剂量敏感性和响应后光稳定性的影响。包含50和100 mM的碘仿(CHI3),溴仿(CHBr3)或氯仿(CHl3)自由基引发剂的不同PRESAGE剂量计,在0至30 Gy的辐射剂量范围内,用6 MV光子进行辐照。使用不同的自由基引发剂对PRESAGE剂量计的敏感性和放射学性质进行了比较。使用分光光度计测量照射前后剂量计的光密度变化。根据所用自由基引发剂的类型和浓度,在PRESAGE剂量计的组成中掺入不同的自由基引发剂会导致剂量计的辐射剂量敏感性和放射学性质发生变化,碘仿显示出最高的剂量反应斜率,随后是溴仿和氯仿。但是,在100 mM碘仿下,有效原子序数明显高于水(Z_(eff)= 16)。发现剂量反应的这种增强直接与碳-卤素键解离能以及本研究中使用的每种自由基引发剂的放射学性质直接相关。此外,无论使用何种三卤甲烷自由基引发剂,PRESAGE剂量计的响应后稳定性在两周内都保持稳定,而PRESAGE剂量计的响应后稳定性和线性变化很小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号