KNI-472 is the first anesthetic system for mice and rats to incorporate a ventilator.It consists of a newly developed syringe pump-type vaporizer and gas monitor that can deliver accurate concentrations of anesthetic gas at an extremely low airflow.In this study,we compared the hemodynamic effects of isoflurane anesthesia using KNI-472 and intraperitoneal pentobarbital anesthesia.In the isoflurane anesthetic group,Institute of Cancer Research(ICR)mice were anesthetized with 5% isoflurane,followed by endotracheal intubation.Subsequently,they were ventilated mechanically,and anesthesia was maintained with 2% isoflurane for a 60-min period using KNI-472.In the pentobarbital anesthetic group,the ICR mice were anesthetized by an intraperitoneal injection of sodium pentobarbital(70 mg/kg).In isoflurane anesthesia,the heart rate(HR)and mean blood pressure(MBP)were stable.In contrast,in pentobarbital anesthesia,MBP decreased in the first stage after the initiation of anesthesia,after which it gradually increased.The intra-group variability in the estimated skin blood flow(SBF)was higher in the pentobarbital anesthesia than that in the isoflurane anesthesia.The PaO2 and PaCO2 values at 15 min after the initiation of pentobarbital anesthesia revealed hypoxia and hypercapnia compared with isoflurane anesthesia.In this study,isoflurane anesthesia using KNI-472,unlike pentobarbital anesthesia,did not induce changes in MBP,SBF,or blood gases.The changes induced by pentobarbital anesthesia were attributed to a change in the depth of anesthesia with time.These results indicate that inhalation anesthesia using KNI-472 is suitable in research on the hemodynamic state in mice.
机译:KNI-472是第一个为小鼠和大鼠配备呼吸机的麻醉系统。它由新开发的注射泵式气化器和气体监测器组成,可以在极低的气流下输送准确的麻醉气体浓度。比较了使用KNI-472麻醉和腹膜内戊巴比妥麻醉对异氟烷麻醉的血液动力学效应。在异氟烷麻醉组中,将5%的异氟烷​​麻醉小鼠癌症研究所(ICR),然后进行气管内插管。使用KNI-472在2%的异氟烷​​中维持麻醉60分钟。在戊巴比妥麻醉组中,腹膜内注射戊巴比妥钠(70 mg / kg)麻醉ICR小鼠。在异氟烷麻醉下,心率(HR)和平均血压(MBP)保持稳定。相反,在戊巴比妥麻醉下,麻醉开始后第一阶段MBP下降,此后又下降戊巴比妥麻醉下估计皮肤血流量(SBF)的组内变异性高于异氟烷麻醉下的差异。戊巴比妥麻醉开始后15分钟的PaO2和PaCO2值显示低氧和高碳酸血症异氟醚麻醉。在这项研究中,与戊巴比妥麻醉不同,使用KNI-472进行的异氟烷麻醉并没有引起MBP,SBF或血气的变化。戊巴比妥麻醉引起的变化归因于麻醉深度随时间的变化。这些结果表明,使用KNI-472进行吸入麻醉适合研究小鼠的血液动力学状态。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号