...
首页> 外文期刊>Radiology >Snapshot inversion recovery: an optimized single-shot T1-weighted inversion-recovery sequence for improved fetal brain anatomic delineation.
【24h】

Snapshot inversion recovery: an optimized single-shot T1-weighted inversion-recovery sequence for improved fetal brain anatomic delineation.

机译:快照反转恢复:优化的单次T1加权反转恢复序列,可改善胎儿脑部解剖学轮廓。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To prospectively evaluate the clinical effectiveness of snapshot inversion recovery (SNAPIR), which is a dedicated optimized inversion-recovery-prepared single-shot fast spin-echo T1-weighted sequence, in the delineation of normal fetal brain anatomy compared with that of the currently used T1-weighted gradient-echo protocol, which often yields images of poor quality due to motion artifacts and inadequate contrast. MATERIALS AND METHODS: This study was approved by the hospital research ethics committee, and informed written consent was obtained from all patients. Forty-one fetuses were examined at 19-37 weeks gestation (mean, 29 weeks gestation) by using both the standard T1-weighted protocol and the optimized T1-weighted SNAPIR protocol with a 1.5-T imager. Two independent blinded observers performed qualitative analysis, evaluating overall diagnostic quality, detailed anatomic delineation, and severity of motion artifacts. Quantitative analysis comprised calculation of contrast ratios (CRs) for the cortical gray matter, subplate, white matter, and cerebrospinal fluid. The Wilcoxon signed rank test was used to compare image rating scores, the paired t test was used to compare CRs, and kappa statistics were used to test interobserver agreement. RESULTS: Both overall diagnostic quality (P < .001) and detailed anatomic delineation (P < .001) were enhanced with SNAPIR compared with the standard T1-weighted acquisition. Also, motion artifacts were less severe (P = .008) and less extensive (P < .001) with SNAPIR. Corresponding CRs were increased with SNAPIR in seven of eight examined regions. CONCLUSION: SNAPIR is a promising robust alternative to the current T1-weighted acquisitions; its role in the detection of disease requires further study.
机译:目的:前瞻性评估快照反转恢复(SNAPIR)的临床效果,该快照是专门优化的反转恢复准备单次快速自旋回波T1加权序列,用于描述正常胎儿脑解剖结构与当前使用的T1加权梯度回波协议,由于运动伪像和对比度不足,该协议通常会产生质量较差的图像。材料与方法:该研究获得医院研究伦理委员会的批准,并获得所有患者的知情同意书。通过使用标准的T1加权方案和优化的T1加权SNAPIR方案以及1.5-T成像仪,在妊娠19-37周(平均,妊娠29周)检查了41例胎儿。两名独立的盲人观察者进行了定性分析,评估了总体诊断质量,详细的解剖描述和运动伪影的严重性。定量分析包括计算皮质灰质,亚板,白质和脑脊液的对比度(CR)。使用Wilcoxon签名等级检验比较图像评分,使用配对t检验比较CR,使用kappa统计量检验观察者之间的一致性。结果:与标准的T1加权采集相比,SNAPIR增强了总体诊断质量(P <.001)和详细的解剖学轮廓(P <.001)。同样,使用SNAPIR,运动伪影不太严重(P = .008),而伪影则不太广泛(P <.001)。 SNAPIR在八个检查区域中的七个区域中增加了相应的CR。结论:SNAPIR是当前T1加权收购的有希望的强大替代方案。其在疾病检测中的作用尚待进一步研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号