首页> 外文期刊>Korean journal of radiology : >Evaluation of the Subscapularis Tendon Tears on 3T Magnetic Resonance Arthrography: Comparison of Diagnostic Performance of T1-Weighted Spectral Presaturation with Inversion-Recovery and T2-Weighted Turbo Spin-Echo Sequences
【24h】

Evaluation of the Subscapularis Tendon Tears on 3T Magnetic Resonance Arthrography: Comparison of Diagnostic Performance of T1-Weighted Spectral Presaturation with Inversion-Recovery and T2-Weighted Turbo Spin-Echo Sequences

机译:肩s下肌腱撕裂在3T磁共振关节造影上的评估:T1加权频谱预饱和与反转恢复和T2加权涡轮自旋回波序列的诊断性能比较

获取原文
           

摘要

Objective To compare the T1-weighted spectral presaturation with inversion-recovery sequences (T1 SPIR) with T2-weighted turbo spin-echo sequences (T2 TSE) on 3T magnetic resonance arthrography (MRA) in the evaluation of the subscapularis (SSC) tendon tear with arthroscopic findings as the reference standard. Materials and Methods This retrospective study included 120 consecutive patients who had undergone MRA within 3 months between April and December 2015. Two musculoskeletal radiologists blinded to the arthroscopic results evaluated T1 SPIR and T2 TSE images in separate sessions for the integrity of the SSC tendon, examining normal/articular-surface partial-thickness tear (PTTa)/full-thickness tear (FTT). Diagnostic performance of T1 SPIR and T2 TSE was calculated with arthroscopic results as the reference standard, and sensitivity, specificity, and accuracy were compared using the McNemar test. Interobserver agreement was measured with kappa (κ) statistics. Results There were 74 SSC tendon tears (36 PTTa and 38 FTT) confirmed by arthroscopy. Significant differences were found in the sensitivity and accuracy between T1 SPIR and T2 TSE using the McNemar test, with respective rates of 95.9–94.6% vs. 71.6–75.7% and 90.8–91.7% vs. 79.2–83.3% for detecting tear; 55.3% vs. 31.6–34.2% and 85.8% vs. 78.3–79.2%, respectively, for FTT; and 91.7–97.2% vs. 58.3–61.1% and 89% vs. 78–79.3%, respectively, for PTTa. Interobserver agreement for T1 SPIR was almost perfect for T1 SPIR (κ = 0.839) and substantial for T2 TSE (κ = 0.769). Conclusion T1-weighted spectral presaturation with inversion-recovery sequences is more sensitive and accurate compared to T2 TSE in detecting SSC tendon tear on 3T MRA.
机译:目的比较3T磁共振关节造影(MRA)上的T1加权频谱预饱和与反转恢复序列(T1 SPIR)和T2加权涡轮自旋回波序列(T2 TSE)在肩in下肌(SSC)肌腱撕裂评估中的作用以关节镜检查结果为参考标准。材料和方法这项回顾性研究纳入了120名连续患者,这些患者在2015年4月至2015年12月的3个月内进行了MRA检查。两名肌肉骨骼放射科医生对关节镜结果不知情,并在单独的会议中评估了T1 SPIR和T2 TSE图像的SSC腱完整性,并进行了检查。正常/关节表面部分厚度撕裂(PTTa)/全层撕裂(FTT)。以关节镜检查结果作为参考标准,计算T1 SPIR和T2 TSE的诊断性能,并使用McNemar测试比较敏感性,特异性和准确性。观察者之间的一致性用κ(κ)统计量来衡量。结果经关节镜检查证实有74例SSC肌腱撕裂(36 PTTa和38 FTT)。使用McNemar测试发现,T1 SPIR和T2 TSE之间的灵敏度和准确性存在显着差异,检测泪液的比率分别为95.9-94.6%,71.6-75.7%和90.8-91.7%和79.2-83.3%。 FTT分别为55.3%和31.6–34.2%和85.8%和78.3–79.2%; PTTa分别为91.7%至97.2%,58.3%至61.1%和89%至78-79.3%。 T1 SPIR的观察者间协议对于T1 SPIR几乎是完美的(κ= 0.839),而对于T2 TSE的观察者之间的一致性(κ= 0.769)。结论与T2 TSE相比,具有反转恢复序列的T1加权频谱预饱和在3T MRA上检测SSC肌腱撕裂方面更为灵敏和准确。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号