首页> 外文期刊>Livestock Science >Comparison of ammonia and greenhouse gas emissions during the fattening of pigs, kept either on fully slatted floor or on deep litter
【24h】

Comparison of ammonia and greenhouse gas emissions during the fattening of pigs, kept either on fully slatted floor or on deep litter

机译:猪肥育过程中氨气和温室气体排放的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Five successive batches of fattening pigs were raised, each during a four month period, on a totally concrete slatted floor in one experimental room and on straw based deep litter in another. The rooms were automatically ventilated to maintain a constant ambient temperature. Available floor space was of 0.75 m2 per pig kept on the slatted floor and 1.20 m2 per pig kept on the deep litter. With this last system, about 46 kg of straw were supplied per pig throughout a fattening period. The slurry pit was emptied and the litter removed after each batch. Once a month, the emissions of ammonia (NH3), nitrous oxide (N2O), methane (CH4), carbon dioxide (CO2), and water vapour (H2O) were measured continuously for 6 consecutive days by infra-red photoacoustic detection. The performance of the animals was not significantly different according to the floor type. Gaseous emissions from pigs raised on the slatted floor and on the deep litter were, respectively, 6.2 and 13.1 g per pig per day for NH3, 0.54 and 1.11 g per pig per day for N2O, 16.3 and 16.0 g per pig per day for CH4, 1.74 and 1.97 kg per pig per day for CO2 and 2.48 and 3.70 kg per pig per day for H2O. Except for the CH4 emissions, all the differences were significant (P<0.001). Thus, pig fattening on deep litter releases nearly 20% more greenhouse gases than on slatted floor, with 2.64 and 2.24 kg of CO2-equivalents, respectively (P<0.001). Whatever the floor type, emissions increased from the beginning to the end of the fattening periods by about 5 times for NH3, 4 times for N2O, 3 times for CH4 and 2 times for CO2 and H2O. Correlation coefficients between CO2-emissions and H2O, NH3 and CH4 emissions were, on average for both floor types, 0.82, 0.77 and 0.74, respectively. Although rearing pigs on straw generally has a good brand image for the consumer, this rearing system produces more pollutant gases than keeping pigs on slatted floors..
机译:在一个实验室的完全混凝土板条地板上,在另一间以稻草为基础的深垫板上,饲养了五批连续的育肥猪,每只猪在四个月内饲养。房间自动通风以保持恒定的环境温度。可用的地板空间是,在板条地板上饲养的每头猪为0.75平方米,在深垫板上饲养的每头猪为1.20平方米。在最后一个系统中,在育肥期间每头猪约供应46公斤稻草。在每批处理之后,排空浆料坑并清除垃圾。每月一次,通过红外光声检测连续六天连续测量氨气(NH3),一氧化二氮(N2O),甲烷(CH4),二氧化碳(CO2)和水蒸气(H2O)的排放。根据地板类型,动物的表现没有显着差异。在板式地板和深垫板上饲养的猪的气体排放量分别为:NH3每头猪每天6.2和13.1 g,N2O每头猪每天0.54和1.11 g,CH4每头猪每天16.3和16.0 g每天每头猪的CO2分别为1.74和1.97千克,H2O每天每头猪分别为2.48和3.70千克。除CH4排放外,所有差异均显着(P <0.001)。因此,深层垫料上的猪肥育释放的温室气体比板条地板上多排放近20%,分别产生2.64和2.24 kg的二氧化碳当量(P <0.001)。无论哪种地板类型,从肥育期的开始到结束,排放的NH3大约增加5倍,N2O大约增加4倍,CH4大约增加3倍,CO2和H2O大约增加2倍。两种地板类型的CO2排放与H2O,NH3和CH4排放之间的相关系数平均分别为0.82、0.77和0.74。尽管将猪饲养在稻草上通常对消费者具有良好的品牌形象,但与将猪饲养在板条地板上相比,这种饲养系统产生的污染物气体更多。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号