首页> 外文期刊>Nutrition >Validity and accuracy of regional bioelectrical impedance devices to determine whole-body fatness.
【24h】

Validity and accuracy of regional bioelectrical impedance devices to determine whole-body fatness.

机译:区域生物电阻抗设备确定全身脂肪的有效性和准确性。

获取原文
获取原文并翻译 | 示例

摘要

Growing emphasis on obesity as a risk factor for chronic diseases and commercial availability of impedance devices for the at-home assessment of body fatness have stimulated the need for a critical evaluation of the validity of these instruments. This study determined the reproducibility and accuracy of two commercial impedance devices that use upper (hand-to-hand) or lower (foot-to-foot) body contact electrode placements in adults with a wide range of body fatness.Body composition was assessed with dual x-ray absorptiometry in apparently healthy adults (62 women and 48 men) ages 21 to 60 y, with a range in body mass index of 18.6 to 40.5 kg/m(2). Variability in body fatness predicted with the regional body impedance devices was determined in 10 adults on 5 consecutive d. A 50-kHz, tetrapolar bioelectrical impedance plethysmograph with surface electrode placements on the upper and lower limbs was used to determine reference regional and whole-body impedance values.Variability in body mass (1%) over 5 dwas less than body fatness predicted with the upper (2-10%) and lower (3-5%) body devices. Regional and whole-body impedance values were different (P < 0.05) in the women, whereas upper and lower body values were lower (P < 0.05) than whole-body impedance in the men. Dual x-ray absorptiometric determinations of body fatness were similar to predictions based on models derived from physical characteristics (age, stature, body mass, and sex) but significantly different (P < 0.05) from estimates from the impedance devices, which underestimated body fatness. Bias in predictions of body fatness with the regional devices was systematically (P < 0.0001) related to body fatness.Use of regional impedance devices to assess body fatness is limited by a lack of precision and accuracy.
机译:越来越多的人将肥胖视为慢性疾病的危险因素,并且在家中评估身体脂肪的阻抗设备的商业可用性刺激了对这些工具的有效性进行严格评估的需求。这项研究确定了两种商业阻抗设备的重现性和准确性,这两种设备在成年肥胖程度较高的成年人中使用上(手)或下(脚)的身体接触电极放置。年龄在21至60岁的明显健康的成年人(62名女性和48名男性)的双X线吸收法,体重指数范围为18.6至40.5 kg / m(2)。连续5天在10位成年人中确定了使用局部人体阻抗设备预测的人体脂肪变异性。在上肢和下肢上放置表面电极的50kHz四极生物电阻抗体积描记器用于确定参考区域和全身阻抗值.5 d内的体重变化(1%)小于用人体预测的身体脂肪上(2-10%)和下(3-5%)身体设备。女性的区域阻抗和全身阻抗值不同(P <0.05),而男性的上,下身阻抗值则较低(P <0.05)。人体脂肪的双X射线吸收光度测定与基于基于物理特征(年龄,身材,体重和性别)的模型的预测相似,但与阻抗设备的估计值相差很大(P <0.05),后者低估了人体脂肪。区域性设备对身体脂肪的预测偏差与系统性肥胖有系统相关性(P <0.0001)。区域性阻抗设备用于评估身体脂肪的方法由于缺乏准确性和准确性而受到限制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号