Pseudocontinuous arterial spin labeling perfusion magnetic resonance imaging--a normative study of reproducibility in the human brain.

机译:伪连续动脉自旋标记灌注磁共振成像-对人脑可重复性的规范研究。

获取原文
获取原文并翻译 | 示例
           

摘要

Pseudocontinuous arterial spin labeling (PCASL), a newly proposed perfusion magnetic resonance imaging (MRI) technique, has the potential of providing a better balance between labeling efficiency and signal-to-noise ratio than conventional ASL methods. The advantage will not be exploitable until adequate reproducibility can be achieved. In this study, we investigated the reproducibility of PCASL on twelve healthy volunteers by taking into account the inclusion of correction for coil sensitivity (CS) and labeling efficiency (alpha). Each subject underwent two identical sessions scheduled two weeks apart. For comparison, pulsed ASL (PASL) imaging was also conducted using the flow-sensitive alternating inversion recovery method. MR imaging was performed on a 3T whole body system using a 12-channel phased array for reception. Blood flow was quantified for gray matter and assessed globally as well as in the flow territories of the internal carotid arteries and posterior cerebral arteries. Experimental results showed that CS accounted for 35% and 60% of inter-session variability in PCASL and PASL, respectively. With CS correction alone, coefficient of variance (CV) remained larger with PCASL than PASL (p=0.02). CV was 12% with CS-corrected PASL and 11% with PCASL when CS and alpha were corrected for in conjunction. We concluded that CS correction is necessary for ASL imaging when using phased array receiver and that after CS correction, PCASL requires alpha correction to provide reproducibility comparable to PASL.
机译:伪连续动脉自旋标记(PCASL)是一种新提出的灌注磁共振成像(MRI)技术,与常规ASL方法相比,具有在标记效率和信噪比之间实现更好平衡的潜力。只有获得足够的可重复性,该优势才能被利用。在这项研究中,我们通过考虑线圈灵敏度(CS)和标记效率(alpha)的校正,研究了PCASL在十二名健康志愿者上的可重复性。每个主题都进行了两次相同的会议,安排了两个星期。为了进行比较,还使用流量敏感的交替反演恢复方法进行了脉冲ASL(PASL)成像。 MR成像是在3T全身系统上使用12通道相控阵进行接收的。对灰质的血流进行定量,并在整体以及颈内动脉和大脑后动脉的血流区域进行评估。实验结果表明,CS分别占PCASL和PASL会话间变异的35%和60%。仅使用CS校正,PCASL的方差系数(CV)仍然大于PASL(p = 0.02)。当CS和alpha一起校正时,CS校正的PASL的CV为12%,PCASL的CV为11%。我们得出的结论是,使用相控阵接收机时,对于ASL成像而言,CS校正是必需的,并且在CS校正之后,PCASL需要进行alpha校正以提供与PASL相当的再现性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号