首页> 外文期刊>Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA >Three-dimensional motion analysis of the human knee joint: Comparison between intra- and post-operative measurements
【24h】

Three-dimensional motion analysis of the human knee joint: Comparison between intra- and post-operative measurements

机译:膝关节的三维运动分析:术中和术后测量值的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To compare intra-operative knee joint kinematic measurements immediately after total knee replacement with those of the same patients post-operatively at 6-month follow-up. Methods: Fifteen patients who underwent total knee arthroplasty were analysed retrospectively. Eight were implanted with one prosthesis design and seven with another. The intra-operative measurements were performed by using a standard knee navigation system. This provided accurate three-dimensional positions and orientations for the femur and tibia by corresponding trackers pinned into the bones. At 6-month follow-up, the patients were analysed by standard three-dimensional video-fluoroscopy of the replaced knee during stair climbing, chair rising and step-up. Relevant three-dimensional positions and orientations were obtained by an iterative shape-matching procedure between the silhouette contours and the CAD-model projections. A number of traditional kinematic parameters were calculated from both measurements to represent the joint motion. Results: Good post-operative replication of the intra-operative measurements was observed for most of the variables analysed. The statistical analysis also supported the good consistency between the intra- and post-operative measurements. Conclusions: Intra-operative kinematic measurements, accessible by a surgical navigation system, are predictive of the following motion performance of the replaced knees as experienced in typical activities of daily living. Level of evidence: Prognostic studies-investigating natural history and evaluating the effect of a patient characteristic, Level II.
机译:目的:比较全膝关节置换术后立即进行的术中膝关节运动学测量与术后6个月随访的相同患者的运动学测量。方法:回顾性分析15例行全膝关节置换术的患者。八只植入了一种假体设计,七只植入了另一种假体。术中测量是通过使用标准的膝盖导航系统进行的。通过固定在骨骼中的相应跟踪器,这为股骨和胫骨提供了精确的三维位置和方向。在6个月的随访中,在爬楼梯,抬高椅子和逐步抬高过程中,通过标准的三维视频透视检查对置换后的膝盖进行了分析。通过轮廓轮廓和CAD模型投影之间的迭代形状匹配过程,获得了相关的三维位置和方向。从两次测量中计算出许多传统的运动学参数,以表示关节运动。结果:对于大多数已分析的变量,均观察到术中测量值良好的术后复制。统计分析还支持术中和术后测量之间的良好一致性。结论:可通过手术导航系统进行的术中运动学测量可预测在典型的日常活动中所经历的膝关节置换术后的运动表现。证据水平:预后研究-研究自然病史并评估患者特征II级的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号