Purpose: Femoral sizing in total knee replacement is important. Either undersizing or oversizing may result in deleterious effects to the clinical outcome after the surgery. There has been no study on the precision and accuracy of femoral sizing and the effect of measurement at different landmarks over the distal femur. This study assesses the intra-observer and inter-observer error of femoral sizing and identifies the effect of the placement site of the anterior referencing tool on femoral sizing. Methods: Five investigators with different clinical experience measured the femoral size of 10 cadaveric specimens twice using three anterior referencing tool. The measurement of the femoral size was repeated at nine designated points on the anterior cortex of the cadaveric femora. Results: Excellent intraobserver and interobserver agreements were obtained using the three anterior referencing tools. When the size on which the majority agreed was regarded as the actual size of the specimen, measurement at the nine designated points on the anterior cortex showed a deviation from the actual size from 6.2 to 46.2 %. Placing the femoral sizer stylus at the middle and 2 cm above the proximal margin of the anterior femoral condyle yielded the highest precision and accuracy. Conclusion: Regardless of the experience of the surgeons, measurement of the femoral size using the three anterior referencing tools is very accurate. Placing the stylus of the femoral sizer at the middle and 2 cm above the proximal margin of the anterior femoral condyle best reflects the actual size of the femur. Level of evidence: Experimental study.
机译:目的:全膝关节置换术中的股骨尺寸很重要。尺寸过小或尺寸过大都可能对手术后的临床结果产生有害影响。尚未进行关于股骨大小的准确性和准确性以及股骨远端不同界标处测量效果的研究。本研究评估了观察者内部和观察者之间的股骨尺码误差,并确定了前参考工具放置位置对股骨尺码的影响。方法:五名具有不同临床经验的研究者使用三个前向参照工具两次测量了10个尸体标本的股骨大小。在尸体股骨前皮质的九个指定点重复进行股骨尺寸的测量。结果:使用三个先前参考工具获得了出色的观察者内部和观察者之间的协议。当大多数人同意的尺寸被认为是标本的实际尺寸时,在前皮质的9个指定点进行的测量显示与实际尺寸之间的偏差为6.2%至46.2%。将股骨定径针放置在股骨前con的近中部上方和上方2 cm处可获得最高的精度和准确性。结论:不管外科医生的经验如何,使用三种前路参考工具测量股骨的大小都是非常准确的。将股骨定径针放置在股骨con的前缘中部和近端边缘上方2 cm处,可以最好地反映股骨的实际大小。证据水平:实验研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号