Purpose: Limited or absent axial rotation of the mobile insert of total knee prostheses could lead to high contact stresses and stresses at the bone-implant interface, which in turn might lead to implant loosening. The aim of this study was to assess knee kinematics and muscle activation and their possible change over time in patients with a highly congruent, mobile-bearing total knee prosthesis. Methods: A prospective series of 11 rheumatoid arthritis patients was included to participate in this fluoroscopic and EMG study; only 7 patients completed the study. Kinematic evaluations took place 7 months, 1 and 2 years post-operatively. Repeated measurements ANOVA and linear mixed-effects model for longitudinal data were used to compare the differences between the follow-ups. Results: There are no significant changes in axial rotations between follow-up moments for the femoral component as well as the mobile insert. The insert remained mobile and followed the femoral component from 0° until approximately 60° of knee flexion. Diverging and reversed axial rotations and translations were seen during the dynamic motions. Conclusions: Knee kinematics and muscle activation do not appear to change in the first 2 post-operative years. Reversed and divergent axial rotations with increasing knee flexion indicate that as soon as the congruency decreases, the femoral component is no longer forced in a certain position by the insert and moves to a self-imposed position. At lower knee flexion angles, the femoral component might be obstructed by the highly congruent insert and therefore might not be able to move freely. Level of evidence: Therapeutic study, Level IV.
机译:目的:全膝关节假体的活动插入物轴向旋转受限或没有轴向旋转,可能会导致较高的接触应力和骨-植入物界面处的应力,进而可能导致植入物松动。这项研究的目的是评估高度一致,可移动轴承的全膝关节假体患者的膝关节运动学和肌肉激活及其随时间的可能变化。方法:前瞻性研究了11例类风湿关节炎患者的荧光镜和肌电图研究。只有7例患者完成了研究。术后7个月,1年和2年进行运动学评估。纵向数据的重复测量ANOVA和线性混合效应模型用于比较随访之间的差异。结果:股骨组件以及活动插入物的跟进力矩之间的轴向旋转没有明显变化。插入物保持活动状态,并从0°直到股骨屈曲约60°跟随股骨组件。在动态运动中看到了发散和反向的轴向旋转和平移。结论:膝关节的运动学和肌肉激活在术后的前2年似乎没有改变。随着膝关节屈曲力的增加,轴向旋转的反向和发散表明,当全合减小时,股骨组件就不再被插入物压迫到某个位置,而是移动到一个自我施加的位置。在较低的膝盖屈曲角度下,高度一致的插入物可能会阻塞股骨组件,因此可能无法自由移动。证据级别:治疗研究,级别IV。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号