首页> 外文期刊>Measurement Science & Technology >Online measurement of water concentration of oil-water mixtures in the flow of pipeline by using eddy current method
【24h】

Online measurement of water concentration of oil-water mixtures in the flow of pipeline by using eddy current method

机译:涡流法在线测量管道中油水混合物中水的含量

获取原文
获取原文并翻译 | 示例
           

摘要

Measurement of water concentration of oil-water mixtures in a pipeline is important in the oil industry. Capacitance, γ-ray and ultrasonic techniques have been developed for the purpose of water-cut measurement for years. In this paper, we demonstrate a new non-contact method, which uses an eddy current sensor to monitor the flow in a pipeline based on the relationship between the water-cut of the flow and the inductance of the sensor. A simulation model and a simple experiment setup are presented. The experimental results have shown that the measurement error for water-cut over the range of 0-100% is less than 4.5%.
机译:测量管道中油水混合物的水浓度在石油工业中很重要。电容,γ射线和超声波技术已被开发用于水含量测量多年。在本文中,我们演示了一种新的非接触式方法,该方法使用涡流传感器根据流量的含水率与传感器的电感之间的关系来监视管道中的流量。给出了仿真模型和简单的实验设置。实验结果表明,含水率在0-100%范围内的测量误差小于4.5%。