首页> 外文期刊>British journal of anaesthesia >Level of agreement between Nexfin non-invasive arterial pressure with invasive arterial pressure measurements in children
【24h】

Level of agreement between Nexfin non-invasive arterial pressure with invasive arterial pressure measurements in children

机译:Nexfin儿童无创动脉压与有创动脉压测量之间的一致性水平

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Background We compared Nexfin non-invasive arterial pressure measurements using a novel small finger cuff with intra-arterial pressure in the paediatric setting in order to establish the level of agreement between both methods.Methods The study included 41 children aged 216 yr admitted for surgery or paediatric intensive care with an intra-arterial catheter as part of standard monitoring. Values of systolic (SAP), diastolic (DAP), and mean arterial pressure (MAP) were obtained simultaneously from the intra-arterial catheter and the non-invasive Nexfin monitor. Data were analysed using intra-class correlation (ICC) coefficients and the BlandAltman analysis.Results A non-invasive arterial pressure signal was obtained in the majority of patients. The reproducibility of arterial pressure measurements over time by both non-invasive and invasive techniques was high, with ICC coefficients ranging from 0.94 to 0.98. The BlandAltman analysis for SAP, DAP, and MAP revealed a bias with 95 limits of agreement of -13.5 (-39.7; 12.8), -0.2 (-12.8; 13.2), and -2.6 (-17.7; 12.5) mm Hg, respectively. Linear regression suggested a weak correlation of SAP and the bias between intra-arterial and Nexfin SAP measurements (intercept 4.9 mm Hg, β -0.29; P0.01).Conclusions Nexfin non-invasive arterial pressure measurements are feasible in paediatric patients. Nexfin accurately reflects the intra-arterial MAP and DAP curves, but seems to underestimate SAP compared with intra-arterial pressure. These results suggest that Nexfin may be used in low-to-moderate risk children without severe systemic hypotension, who require beat-to-beat haemodynamic monitoring but do not have an indication for invasive measurements.
机译:背景为了比较两种方法的一致性,我们将儿科环境中使用新型小手指袖带与动脉内压的Nexfin非侵入性动脉压测量结果进行了比较。方法该研究包括41名216岁的儿童入院接受手术或作为标准监测的一部分,使用动脉内导管进行小儿重症监护。从动脉内导管和非侵入性Nexfin监护仪同时获得收缩压(SAP),舒张压(DAP)和平均动脉压(MAP)的值。使用组内相关系数(ICC)和BlandAltman分析法对数据进行分析。结果大多数患者均获得了非侵入性动脉压信号。通过无创和有创技术,随着时间的推移,动脉压测量的可重复性很高,ICC系数为0.94至0.98。针对SAP,DAP和MAP的BlandAltman分析显示,有95个一致极限的偏差分别为-13.5(-39.7; 12.8),-0.2(-12.8; 13.2)和-2.6(-17.7; 12.5)mm Hg。 。线性回归表明SAP的相关性较弱,动脉内和Nexfin SAP测量之间存在偏差(截距4.9 mm Hg,β-0.29; P0.01)。结论Nexfin无创动脉压测量在儿科患者中是可行的。 Nexfin可以准确反映动脉内MAP和DAP曲线,但与动脉内压相比似乎低估了SAP。这些结果表明,Nexfin可以用于没有严重系统性低血压的中低风险儿童,这些儿童需要逐次进行血流动力学监测,但没有侵入性测量的指征。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号