首页> 外文期刊>Medical Physics >Alpha image reconstruction (AIR): A new iterative CT image reconstruction approach using voxel-wise alpha blending
【24h】

Alpha image reconstruction (AIR): A new iterative CT image reconstruction approach using voxel-wise alpha blending

机译:Alpha图像重建(AIR):一种新的迭代CT图像重建方法,使用三维像素混合技术

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporatea priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger the loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast factor for contrast-resolution plots. Furthermore, the authors calculate the contrast-to-noise ratio with the low contrast disks and the authors compare the agreement of the reconstructions with the ground truth by calculating the normalized cross-correlation and the root-mean-square deviation. To evaluate the clinical performance of the proposed method, the authors reconstruct patient data acquired with a Somatom Definition Flash dual source CT scanner (Siemens Healthcare, Forchheim, Germany). Results: The results of the simulation study show that among the compared algorithms AIR achieves the highest resolution and the highest agreement with the ground truth. Compared to the reference FBP reconstruction AIR is able to reduce the relative pixel noise by up to 50% and at the same time achieve a higher resolution by maintaining the edge information from the basis images. These results can be confirmed with the patient data. Conclusions: To evaluate the AIR algorithm simulated and measured patient data of a state-of-the-art clinical CT system were processed. It is shown, that generating CT images through the reconstruction of weighting coefficients has the potential to improve the resolution noise trade-off and thus to improve the dose usage in clinical CT.
机译:目的:迭代图像重建在临床常规操作中越来越受到关注,因为它有望减少图像噪声(从而减少患者剂量),减少伪影或提高空间分辨率。但是,在供应商和研究人员之间,如何最好地实现这些目标尚未达成共识。通常的方法是,例如,通过向成本函数添加其他约束,将先验知识纳入迭代图像重建中,这会惩罚相邻体素之间的变化。但是,这种正则化方法通常会带来分辨率噪声的折衷,因为正则化越强,从而噪声的减少,空间分辨率的损失就越强,因此解剖细节的损失也就越大。作者提出了一种试图改善这种折衷的方法。所提出的重建算法称为Alpha图像重建(AIR)。首先从生成基础图像开始,这些图像强调某些所需的图像属性,例如高分辨率或低噪声。 AIR算法可重建特定于体素的加权系数,该系数可用于组合基础图像。通过组合每个基本图像的所需属性,可以生成具有较低噪声并保持高对比度分辨率的图像,从而改善分辨率噪声的权衡。方法:所有模拟和重建都在本机扇形束几何中进行。模拟具有分辨率条图案和低对比度光盘的水模型。具有Ram-Lak核的滤波反投影(FBP)重建用作参考重建。将AIR的结果与FBP结果以及使用总变化量作为正则化的惩罚加权最小二乘重建进行比较。这些模拟基于Siemens Somatom Definition Flash扫描仪的几何形状。为了定量评估图像质量,作者通过分辨率模式分析线轮廓,以定义对比度分辨率图的对比度因子。此外,作者使用低对比度的光盘来计算对比度-噪声比,并通过计算归一化互相关和均方根偏差来比较重建与地面真实性的一致性。为了评估所提出方法的临床性能,作者重建了使用Somatom Definition Flash双源CT扫描仪(Siemens Healthcare,Forchheim,德国)获取的患者数据。结果:仿真研究的结果表明,在比较的算法中,AIR获得了最高的分辨率和与地面真实性的最高一致性。与参考FBP重建相比,AIR能够将相对像素噪声降低多达50%,并同时通过保留基础图像的边缘信息来实现更高的分辨率。这些结果可以通过患者数据得到确认。结论:为了评估AIR算法,处理了最新的临床CT系统的模拟和测量患者数据。结果表明,通过重建权重系数来生成CT图像具有改善分辨率噪声权衡的潜力,从而可以改善临床CT的剂量使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号