252Cf is a neutron emitting radioisotope which has promise for both standard brachytherapy and neutron capture enhanced brachytherapy. In this study, experimental measurements and calculations were used to determine the thermal neutron fluence rate, phi(th) [n cm(-2) s(-1) mg(-1)], in the vicinity of 252Cf applicator tube (AT) type sources. Results of these measurements were confirmed with Monte Carlo calculations performed in a distributed manner on multiple workstations using MCNP. Three studies were executed: (1) relative phi(th) as a function of distance from a 252Cf AT source in an A-150 tissue equivalent plastic phantom using thermoluminescent dosimeters (TLDs) of varying 6Li/Li enrichment, (2) phi(th) measured with gold foils in a 114 liter water phantom 5 cm from two 252Cf AT sources, and (3) calculations of the impact of phantom material composition (e.g., A-150, water, brain, muscle) on phi(th) from moderated 252Cf fast neutrons. TLD results and Monte Carlo calculations in A-150 of relative phi(th) typically agreed within 1% and at most differed by 3% for distances from 1 to 6 cm. Foil measurements followed the ASTM E 262-86e protocol, and the ratio of activated plain and Cd encased gold foils (7.31) agreed well with the calculated ratio (7.26). Measured phi(th) at 5 cm (1.70+/-0.10 x 10(7) n cm(-2) s(-1) mg(-1)) was 10% greater than that determined using MCNP (1.55+/-0.12 x 10(7) n cm(-2) s(-1) mg(-1)), but was within the combined uncertainties. Compared with A-150 at a distance of 1 cm, phi(th) was 20%, 22%, and 32% less for water, brain, and muscle, respectively; these ratios decreased to 16%, 16%, and 24% less, respectively, at a distance of 5 cm from the source in a 15 cm diameter phantom. Comparisons of these results generally agreed with those in the literature for a value of 2 x 10(7) n cm(-2) s(-1) mg(-1) in water at 3 cm.
机译:252Cf是一种发射中子的放射性同位素,有望用于标准近距离放射治疗和中子捕获增强近距离放射治疗。在这项研究中,实验测量和计算用于确定252Cf施加器管(AT)附近的热中子注量率phi(th)[n cm(-2)s(-1)mg(-1)]。 )类型来源。这些测量的结果通过使用MCNP在多个工作站上以分布式方式进行的蒙特卡洛计算得到了证实。进行了三项研究:(1)相对phi(th)是使用变化的6Li / Li富集的热发光剂量计(TLD)在A-150组织等效塑料体模中距252Cf AT源的距离的函数,(2)phi( th)在距两个252Cf AT来源5 cm的114升水幻影中用金箔测量,以及(3)计算幻影材料成分(例如A-150,水,脑,肌肉)对phi(th)的影响来自252Cf慢速中子。 TLD结果和A-150中相对phi(th)的蒙特卡洛计算通常在1%范围内一致,对于1至6 cm的距离,最大相差3%。箔片测量遵循ASTM E 262-86e协议,活化的平纹纸和Cd包裹的金箔的比例(7.31)与计算的比例(7.26)非常吻合。在5 cm(1.70 +/- 0.10 x 10(7)n cm(-2)s(-1)mg(-1))处测得的phi(th)比使用MCNP测定的phi(th)大10%(1.55 +/- 0.12 x 10(7)n cm(-2)s(-1)mg(-1)),但在合并的不确定性范围内。与A-150相比,在1厘米处,水,大脑和肌肉的phi(th)分别降低了20%,22%和32%。在直径为15 cm的幻影中,距光源5 cm的距离时,这些比率分别降低到16%,16%和24%。这些结果的比较通常与文献中的结果一致,在3 cm的水中值为2 x 10(7)n cm(-2)s(-1)mg(-1)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号