首页> 外文期刊>Medical dosimetry: official journal of the American Association of Medical Dosimetrists >Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications
【24h】

Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications

机译:用于高剂量率近距离放射治疗的两种治疗计划系统的剂量学评估

获取原文
获取原文并翻译 | 示例
       

摘要

Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.
机译:各种治疗计划系统用于设计使用高剂量率近距离放射疗法治疗宫颈癌的计划。这项研究的目的是对两种来自瓦里安医疗系统的治疗计划系统(ABACUS和BrachyVision)进行剂量学比较。使用ABACUS(版本3.1)和BrachyVision(版本6.5)计划系统比较了单个驻留位置生成的Ir-192辐射源的剂量分布。计划使用正交X线照片在这两个系统上计划10个腔内应用的患者。在处方点(A点,左右)和参考点RU,LU,RM,LM,膀胱和直肠计算剂量。对于单停留位置,沿垂直平分线的点的剂量几乎没有差异。这些点的ABACUS和BrachyVision之间的平均差为1.88%。 ABACUS和BrachyVision计算出的朝向电缆远端的平均剂量差异为3.78%,而沿近端的平均差异为19.82%。对于患者而言,ABACUS和BrachyVision计划的处方点剂量之间存在大约2%的差异。参考点的剂量差异为0.4-1.5%。对于膀胱和直肠,差异分别为5.2%和13.5%。直肠各点之间的剂量差异具有统计学意义。两个治疗计划系统执行的剂量计算之间存在相当大的差异。可以看出,这些差异是由这两种系统采用的计算方法不同引起的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号