On the basis of altering pH-values the ageing behaviour of frost resistant heating waters was tested.The investigations were carried out with pure glycol-water-mixtures and finished products underplant conditions as well as in the presence of air and metals at temperatures of 30, 60 and 90℃. It hasbeen proved that the ageing load was unimportant in modern heating systems. In order to bridgewinter periods without heating pure glycol can be used as anti freeze with corrosion chemicaladvantages after draining the heating plant. For long term protection anti freeze mixtures containinginhibitors are certainly more secure.
机译:在改变pH值的基础上,测试了防冻热水的老化行为。在工厂条件下以及温度为30的空气和金属存在下,使用纯乙二醇-水混合物和成品进行了研究。 ,60和90℃。已经证明,老化负荷在现代供暖系统中并不重要。为了在不加热的情况下过冬,纯净的乙二醇可以在排空加热设备后用作具有抗腐蚀化学优点的防冻剂。对于长期保护,含有抑制剂的防冻混合物肯定更安全。