In accordance with NCCLS guideline M31-A2, the DVG working group "antimicrobial resistance" developed a standard operating procedure (SOP) for the determination of the minimal inhibitory concentration (MIC) of antimicrobial agents by broth microdilution. This SOP was evaluated for its fitness for use in a national interlaboratory test. A total of 32 participating laboratories tested five strains (including two internationally accepted reference strains and three field strains representing in total three different bacterial species) three times at a one week interval each, using uniform microtitre plates. In 31 of the 32 laboratories more than 80% of MIC determinations performed yielded values in the expected range. In total 94.0% of the results were reproducible, with a lesser deviation of 4.0% from the expected values for laboratories performing MIC determination as a matter of routine (46.9%), compared to 7.9% for laboratories without such routine (53.1%). Comparing the consistency of results on the basis of the tested strains, a higher reproducibility of the results was observed for reference strains (96.1%) than for field strains (92.6%). In particular results obtained for the Streptococcus uberis field strain were afflicted with a higher error ratio (98 deviations from the expected values). Among the tested antimicrobial agents, a higher variability of results was recorded only for gentamicin with 16.7% divergent MIC determinations (mean value 6.0%). The high reproducibility of the results confirmed by this interlaboratory study underlines the robustness of the developed SOP as well as broth microdilutions as the method of choice for MIC determina tion.
机译:根据NCCLS准则M31-A2,DVG工作组“抗药性”开发了一种标准操作程序(SOP),用于通过肉汤微量稀释测定抗微生物剂的最低抑菌浓度(MIC)。对该SOP进行了适合在国家实验室间测试中使用的评估。总共32个参与实验室使用均匀的微量滴定板,每三个星期对五个菌株(包括两个国际公认的参考菌株和三个代表总共三种不同细菌物种的田间菌株)进行了三次测试。在32个实验室中的31个中,超过80%的MIC测定值在预期范围内。总计94.0%的结果是可重现的,与常规情况下进行MIC测定的实验室的预期值相比,偏差较小(46.9%),而没有常规方法的实验室的预期偏差则为7.9%(53.1%)。在测试菌株的基础上比较结果的一致性,与参考菌株(92.6%)相比,参考菌株(96.1%)的结果再现性更高。特别是,乳房链球菌田间菌株获得的结果受到较高的错误率(与预期值有98个偏差)的困扰。在所测试的抗菌剂中,仅庆大霉素的MIC测定值差异为16.7%(均值6.0%),因此记录的结果差异更大。该实验室间研究证实了结果的高度可重复性,这突显了开发的SOP以及肉汤微稀释液作为MIC测定方法的稳健性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号