...
首页> 外文期刊>Gait & posture >Reliability and validity of an accelerometry based measure of static and dynamic postural stability in healthy and active individuals
【24h】

Reliability and validity of an accelerometry based measure of static and dynamic postural stability in healthy and active individuals

机译:基于加速度计的健康和活动个体静态和动态姿势稳定性度量的可靠性和有效性

获取原文
获取原文并翻译 | 示例
           

摘要

Postural stability is an important measure in both research and clinical practice. A portable, easy to use device that can provide higher resolution than current clinical tests may allow for better identification of patients or athletes with postural stability deficits. The purpose of this study was to evaluate the ability of a tri-axial accelerometer to quantify postural stability in a healthy athletic population. Ten subjects were recruited to determine the reliability of the accelerometer to measure dynamic postural stability and thirteen were recruited to compare the accelerometer measures across tasks of varying difficulty. Subjects were asked to complete four static postural stability tasks with eyes open and eyes closed and two dynamic postural stability tasks for a total of ten tasks. During each task postural stability was measured using a tri-axial accelerometer and force platform. Differences between postural stability scores between tasks and the correlation between the two measures were assessed. The accelerometer demonstrated moderate to good test-retest reliability (ICC = 0.732 to 0.899). Only the medial-lateral axis of the accelerometer showed significant differences between static tasks but all directions were able to show significant differences between static and dynamic tasks. Additionally, Spearman's ranked correlations showed little to no correlation between the accelerometer and force platform scores. Accelerometers are a reliability tool for postural stability that measure low difficulty tasks best in the medial-lateral direction. Low correlation between the accelerometer and force platform suggest that these two methods are not measuring the same components of postural stability. (C) 2014 Elsevier B.V. All rights reserved.
机译:姿势稳定性是研究和临床实践中的重要措施。便携式,易于使用的设备可以提供比当前临床测试更高的分辨率,可以更好地识别具有姿势稳定性缺陷的患者或运动员。本研究的目的是评估三轴加速度计在健康运动人群中量化姿势稳定性的能力。招募了10名受试者来确定加速度计测量动态姿势稳定性的可靠性,招募了13名受试者来比较不同难度任务之间的加速度计测量值。要求受试者睁开眼睛并闭上眼睛完成四个静态姿势稳定任务,以及两个动态姿势稳定任务,总共十个任务。在每个任务期间,使用三轴加速度计和受力平台测量姿势稳定性。评估任务之间的姿势稳定性评分之间的差异以及两种方法之间的相关性。加速度计显示出中等到良好的重测可靠性(ICC = 0.732至0.899)。仅加速度计的中外轴在静态任务之间显示出显着差异,但所有方向在静态任务和动态任务之间均显示出显着差异。此外,Spearman的排名相关性显示加速度计和测力平台得分之​​间几乎没有相关性。加速度计是一种用于姿势稳定性的可靠性工具,可在内侧-外侧方向上最佳地测量低难度任务。加速度计和受力平台之间的相关性较低,表明这两种方法无法测量姿势稳定性的相同组成部分。 (C)2014 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号