PURPOSE: To evaluate the intraobserver and interobserver reproducibility of the automatic full field perfusion image analysis (AFFPIA) program on Heidelberg Retina Flowmeter (HRF) derived perfusion images in a multicentre study group. METHODS: A total of 10 subjects were consecutively recruited in the study. One eye was randomly selected for each patient. Blood flow was assessed by HRF and flow measurements were analyzed by using the AFFPIA program. AFFPIA calculates the Doppler frequency shift and the haemodynamic variables: flow for each pixel. Intraobserver and interobserver reproducibility was calculated for AFFPIA program. The retinal blood flow was calculated in the superior and inferior section, furthermore, each section was divided into three parts: the temporal area, the nasal, and the rim area, as for software, but only the temporal and nasal areas were considered in this study. The blood flow and the area considered were evaluated for each part. RESULTS: When the intraobserver and intraimagereproducibility was studied, the coefficient of variation ranged from 0.4 to 1.9%. When the interobserver and intraimage reproducibility was studied, the retinal blood flow coefficient of variation ranged from 0.52 to 3.30% for the supero-temporal area, from 0.13 to 2.67% for the inferotemporal area, from 0.15 to 2.75% for the supero-nasal area, and from 0.04 to 5.65% for the infero-nasal area. CONCLUSION: Our results with AFFPIA showed an interobserver coefficient of variation of retinal blood flow measurements always less than 6% in both temporal and nasal areas. No significant difference was found among the four observers for the flow measurements.
机译:目的:在多中心研究组中,评估海德堡视网膜流量计(HRF)衍生的灌注图像在自动全视野灌注图像分析(AFFPIA)程序中观察者之间和观察者之间的可重复性。方法:本研究共招募了10名受试者。为每位患者随机选择一只眼睛。通过HRF评估血流,并使用AFFPIA程序分析血流测量值。 AFFPIA计算多普勒频移和血流动力学变量:每个像素的流量。对于AFFPIA程序,计算了观察者内和观察者间的可重复性。在软件的上,下部分计算视网膜血流,此外,将每个部分分为三个部分:颞侧区域,鼻侧和边缘区域(就软件而言),但在此仅考虑颞侧和鼻侧区域研究。对每个部位的血流量和所考虑的面积进行评估。结果:当研究观察者内和图像内再现性时,变异系数在0.4%至1.9%之间。当研究观察者之间和图像内的再现性时,颞上区域的视网膜血流变异系数范围为0.52至3.30%,颞下区域为0.13至2.67%,鼻上区域为0.15至2.75% ,鼻下区域则为0.04至5.65%。结论:我们的AFFPIA结果显示,在颞和鼻区域,观察者之间的视网膜血流测量变异系数始终小于6%。在流量测量的四个观察者之间没有发现显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号